Authors: Victoria R. Zeger, Bhawana Thapa, Danial Shamsaei, Jessica F. DeLair, Tristen L. Taylor, Jared L. Anderson
Categories: Review
Source: Analytical Chemistry
Technological Advances, and Future Outlook
Authors: Victoria R. Zeger, Bhawana Thapa, Danial Shamsaei, Jessica F. DeLair, Tristen L. Taylor, Jared L. Anderson
The development of new analytical methods most often focus on novel materials used to impart selectivity or sensitivity to the protocol. Ionic liquids (ILs) are a class of solvents that have been extensively explored as promising materials for various applications and continue to be explored due to their tunable physicochemical properties. These materials possess melting temperatures below 100 °C and can interact with analytes through a multitude of interactions afforded by their readily tunable chemical structure.^1^ These interactions include electrostatic, dispersive, hydrogen bonding, π–π, and dipolar interactions and can be modulated or strengthened based on the functional groups present within the chemical structure.^2^ ILs consist predominately of organic cations and either inorganic or organic anions, both of which can be functionalized with desired moieties. Common cation and anions found in IL chemical structures are presented in Figure 1. The unique polarity afforded by the ionic structure has also led to their increasing use in areas including sample preparation, chemical separations, electrochemistry, mass spectrometry, and spectroscopy.^3−7^

ILs are often referred to as “designer solvents” because most of their physicochemical properties can be tuned by interchanging different cations and anions. Specific analytical applications may require solvents to exhibit a certain melting temperature, viscosity, volatility, conductivity, and/or solubility to meet the constraints of the method, and often these requirements cannot be achieved with traditional solvents. To overcome the limitation of organic solvents, many studies have sought to understand the influence that the IL chemical structure plays in dictating their behavior.^8−11^ In this review, specific properties of ILs are discussed when related to the success of the application, but readers are encouraged to explore the chapter by Zhou et al. in Ionic Liquids Further UnCOILed: Critical Expert Overviews for further information regarding relationships between IL chemical structure and physicochemical properties.^12^
By incorporating certain functional groups into the IL chemical structure, subclasses of ILs have emerged including polymeric ionic liquids (PILs),^13,14^ magnetic ionic liquids (MILs),^15^ zwitterionic ionic liquids (ZILs),^16^ dicationic liquids (DILs),^17^ chiral ionic liquids (CILs),^18^ and fluorescent ionic liquids (FILs).^19,20^ Polymerizable IL monomers can be designed by incorporating reactive functional groups into the IL chemical structure, which subsequently undergo polymerization to form PILs. PILs have been applied in various geometries including thin films,^21^ cylindrical columns,^22^ and spheres.^23^ They offer improved thermal and chemical stability over traditional ILs and have been employed in a variety of analytical applications ranging from sorbents in sample preparation methods to signal enhancers in mass spectrometry (MS) and spectroscopy methods.^24,25^ ZILs consist of chemically bonded cations and anions and exhibit IL-like properties, such as low volatility, lower melting points, and moderate to high thermal stability.^26^ Most notably, the higher viscosity and increased polarity of ZILs have led to their use as extraction solvents as well as gas and liquid chromatographic stationary phases.^27−29^ DILs, consisting of two tethered cations, have been studied in a variety of applications from extractions to separations, and have become a popular choice as charge inverters to improve sensitivity in the MS detection of negatively charged analytes in positive ionization mode.^17,30,31^ CILs are a distinct class of ILs consisting of cations or anions with a chiral center. The specific stereochemistry of the CIL allows for stronger interactions with a targeted enantiomer, resulting in enantiomeric separations.^18^ CILs are often employed in chiral separations with cyclodextrins to enhance enantioseparations.^32^ Lastly, FILs have been uniquely designed with fluorescent anions in their chemical structure to improve the detection of analytes.^20^ FIL-based detection methods have also been used with smartphone detectors or colorimetric assays for methods involving point-of-care and on-site detection.^33,34^
The current review provides an update on the application of ILs in analytical chemistry since our last review published in 2019.^35^ While this review is meant to be comprehensive, specific emphasis is given to studies demonstrating innovative applications of ILs in each of the subdisciplines within the field of analytical chemistry. The review is organized into three main topics, (1) chemical separations including sample preparation, chromatographic separations, membrane separations, and electrokinetic separations; (2) electrochemical sensing; and (3) other methods using mass spectrometry and spectroscopy. Table 1 defines common terminology used throughout this review and within the analytical chemistry disciplines; abbreviations and terminologies related to ILs will be defined within the text. To keep IL abbreviations consistent through the review, a uniform abbreviation style is used and may differ slightly from that reported in the original published articles.
Sample preparation is often a crucial step in chemical analysis as it separates target analytes from interfering substances and concentrates them for improved detection. It is especially critical for biological and environmental samples as direct introduction of these complex matrices into analytical instrumentation is often undesirable due to inherent disadvantages, and analyte concentrations are often too low for detection by common analytical instrumentation.^36,37^ ILs have been long used as solvents for the extraction of analytes from complex matrices. ILs have been employed in liquid–liquid extraction (LLE) as a selective and environmentally friendly alternative to conventional organic solvents.^38,39^ However, the high viscosity and costs of ILs compared to traditional organic solvents are often seen as limitations for their use in extractions that require larger volumes. These challenges have been mitigated by employing ILs in microextraction (ME) procedures, allowing for the full exploitation of their solvation power.^40^ Microextractions employ very small volumes of extraction solvent relative to the sample volume and are commonly applied as a preconcentration method prior to analysis.^41^ ILs have gained widespread popularity in both solvent-based and sorption-based ME techniques, owing to their distinctive characteristics and overall versatility.
Phase Microextractions (LPMEs)
Dispersive liquid–liquid microextraction (DLLME) and single drop microextraction (SDME) have emerged as innovative techniques for applying ILs in ME studies.^42,43^ DLLME was first introduced by Rezaee et al. in 2006 where they developed a simple and rapid method for extracting organic compounds from aqueous samples.^44^ DLLME uses a ternary solvent system, where a water-immiscible extraction solvent (commonly denser than water) is mixed with a water-miscible disperser solvent. The mixture is quickly injected into the aqueous sample, causing the extraction solvent to disperse into fine droplets and a cloudy solution to be formed. The contact area between the solvent and sample is increased resulting in accelerated equilibrium between the two phases. Advantages of DLLME methods include simplicity of operation, speed, low cost, and high analyte recovery and enrichment factors. However, DLLME is frequently criticized for the use of harmful chlorinated solvents for extraction.
ILs have emerged as alternative solvents due
to their lower toxicity (compared to chlorinated solvents), high structural
tunability, and higher density compared to water. Liu et al. was the
first to report the use of ILs in DLLME for detecting four heterocyclic
insecticides in water samples.^45^ Numerous
studies have explored and modified IL-based DLLME methods, leading
to exciting improvements and applications. Various approaches have
been developed to eliminate the use of organic disperser solvents,
including ultrasound-assisted, vortex-assisted, microwave-assisted,
and air-assisted DLLME techniques; however, these often require external
energy for dispersion of extraction solvents.^46^ Piao et al. reported for the first time an acidic task-specific
IL-based effervescence-assisted ME method to determine triazine herbicides
in tea beverages^47^ in which the herbicides
are known to have potential adverse effects, including hormone disruption,
birth defects, and reproductive cancers.^48^ In effervescence-assisted ME methods, the extraction solvents or
adsorbents are dispersed using carbon dioxide bubbles produced from
a straightforward reaction between carbonate and acid in an aqueous
solution. This method utilized the 1-butyl-3-methylimidazolium hydrogen
sulfate ([C4MIm^+^][HSO4^–^]) IL, where the cationic group acted as the extractant while the
anionic group served as a substitute for traditional acids. This reaction
enhanced mass transfer between the extraction solvent and analytes
without requiring an external energy source. Following dispersion,
the ion-exchange reagent ammonium hexafluorophosphate was introduced,
resulting in replacement of the hydrophilic IL with the hydrophobic
[C4MIm^+^][PF6^–^]
IL, allowing for easy recovery from the aqueous solution.
Effervescence-assisted
DLLME requires centrifugation to collect
the extraction solvent, which is often regarded as the most time-consuming
step in IL-DLLME. Thus, recent studies have focused on utilizing MIL-based
DLLME, where MILs can be easily separated using a simple permanent
magnet. MILs are a subclass of ILs that incorporate paramagnetic atoms
(i.e., transition metals or lanthanide metals) within their chemical
structure. These tunable materials retain the defining properties
of ILs while possessing unique physicochemical characteristics that
make them responsive to external magnetic fields.^49^ Fiorentini et al. developed a MIL-based DLLME method where
the trihexyl(tetradecyl)phosphonium tetrachloroferrate (III) ([P6,6,6,14^+^][FeCl4^–^])
MIL was used as an extraction solvent for the capture and determination
of trace levels of arsenic (As(III)) in honey.^50^ As(III) was preconcentrated by chelating with ammonium
diethyldithiophosphate under acidic conditions and then extracted
by the MIL with acetonitrile as a dispersive solvent. Magnetic separation
of the analyte-containing MIL phase eliminated the need for centrifugation.
Trujillo-Rodríguez et al. developed an approach where a new
class of MILs was used for in situ DLLME to achieve
higher enrichment factors than conventional DLLME, while also removing
the centrifugation step.^51^ Commonly employed
MILs in analytical methodologies contain paramagnetic anions such
as tetrachloroferrate(III) ([FeCl4^–^]),
bromotrichloroferrate(III) ([FeBrCl3^–^]), tetrachloromanganate(II) ([MnCl4^2–^]), tris(hexafluoroacetylaceto)nickelate(II) ([Ni(hfacac)^3–^]), or tris(hexafluoroacetylaceto)dysprosate(III) ([Dy(hfacac)^4–^]). These anions often render MILs unsuitable for in situ applications for many reasons, but most apparent
is that the paramagnetic component can be exchanged during the metathesis
reaction, hindering subsequent magnetic separation. The newly designed
MILs consist of cations featuring nickel(II) centers coordinated with
four N-alkylimidazole ligands and chloride anions,
which can undergo a metathesis reaction with the bis[(trifluoromethyl)sulfonyl]imide
([NTf2^–^]) anion. This research led to
a study by Bowers et al. utilizing the concept of MIL-based in situ DLLME for the extraction of long and short double-stranded
DNA.^52^ A very recent study by Qiao et al.
reported the use of a multimagnetic center MIL (MMIL) featuring paramagnetic
metals in both the cation and anion as extractants in DLLME for the
determination of parabens in beverages. To further enhance paraben
enrichment, the method incorporated a back-extraction step through in situ decomposition of the MMIL.^53^
Another LPME technique that has also gained traction for its
unique
advantages is single microdroplet microextraction (SDME). Although
SDME was the first LPME technique introduced, research on this topic
has been less prevalent in recent years compared to DLLME. In this
method, a drop (typically few microliters) of a water-immiscible solvent
serves as the extraction phase and is suspended from a syringe needle.
The microdroplet is either immersed in a stirred aqueous solution
or exposed to the headspace for a specific duration, after which it
is retracted and analyzed.^54^ SDME has gained
popularity due to its low cost, significant reduction in sample size,
and minimal use of extraction solvents, all while offering high analyte
enrichment. ILs have been investigated as alternative extraction solvents
given their low vapor pressure and high viscosity that minimize solvent
evaporation and enhance droplet stability.^55^ Li et al. reported the use of the 1-butyl-3-methylimidazolium ([C4MIm^+^][NTf2^–^] IL as
extraction solvent for the determination of trace methanesulfonates
using headspace SDME. Methanesulfonates are potential genotoxic agents
formed through the reaction between residual solvents and methanesulfonic
acid during synthesis and the manufacturing of drug substances.^56^ The selective and sensitive determination of
methanesulfonates, such as methylmethanesulfonate, ethylmethanesulfonate
and isopropyl methanesulfonate, in drug substances possess significant
challenges due to the complexities of the drug matrix. Previously
proposed solutions were ineffective in mitigating the matrix effects;
however, utilizing the [C4MIm^+^][NTf2^–^] IL in headspace SDME mode after derivatizing
the analytes not only eliminated the matrix effect but also resulted
in good recoveries.
PILs are
formed through the
polymerization of IL monomers, with or without an IL cross-linker.
PILs have gained prominence as sorbents in various ME techniques,
including solid-phsae microextraction (SPME),^27,57^ thin film microextraction (TFME),^58,59^ and microextraction
by packed sorbent (MEPS).^60,61^ Among these techniques,
SPME has been widely used owing to its ability to detect a broad range
of analytes in food, environmental, biological, and pharmaceutical
samples.^62−64^ In SPME, small volumes of sorbents are either coated
or immobilized on a solid support, which enhances their stability
during the extraction process. It is a preconcentration technique
based on the partitioning of analytes between an extraction phase
and sample matrix, either in headspace or direct-immersion mode. SPME
offers significant advantages over traditional extraction methods
since it is rapid and integrates sample collection, extraction, and
analyte enrichment from the sample matrix into a single step.^65^ It is also simple and easy to automate and is
fully compatible with chromatographic systems. Despite these benefits,
SPME is limited by the number of commercially available sorbent coatings,
which has driven increased research into designing new sorbents.^27^ PILs have emerged as promising alternatives
not only due to the tunable chemical structures inherent to IL monomers
and cross-linkers but also due to their superior thermal and chemical
stability compared to neat ILs.^66^ These
properties have led to widespread and innovative application of PILs
as sorbents in SPME, enhancing the selectivity and efficiency of analyte
detection across a broad range of fields. In a study by Yavir et al.,
PIL sorbent coatings were synthesized with nickel metal centers to
extract volatile and semivolatile amines from water samples using
HS-SPME.^67^ The study highlights the use
of the nickel-based PIL, composed of (tetra(3-vinylimidazolium)nickel
bis[(trifluoromethyl)sulfonyl]imide ([Ni(VIM)4][NTf2]2) IL monomer, as having unique selectivity toward
amines as observed with nickel-containing ILs. Amines are toxic and
hazardous to humans and animals and can react with nitrosylating agents
to form carcinogenic N-nitroamines, further emphasizing the significance
of the study.^68^
Although SPME most
commonly uses a fiber-type geometry, several innovative formats, such
as in-tube SPME, have been developed. In-tube SPME was designed to
facilitate direct, online coupling of SPME with high performance liquid
chromatography (HPLC) systems. This system employs a capillary column
segment as the extraction device, where analytes from the diluted
sample are concentrated into the stationary phase through repeated
draw/eject cycles or by flowing through the capillary using a microflow
pump or autosampler. The extracted analytes are then eluted off by
the mobile phase and transferred to the HPLC column, thereby reducing
analysis times and often improving accuracy and precision.^69^ In-tube SPME has seen numerous innovative applications
since its introduction in the 1990s. A recent, notable advancement
by Souza et al. involved developing PIL coated open tubular capillary
columns for online in-tube SPME combined with ultrahigh performance
liquid chromatography (UHPLC) coupled to MS/MS. This method was used
to analyze endocannabinoids (eCBs) in plasma samples from patients
with Parkinson’s disease.^70^ The
endocannabinoid system plays an important role in controlling signals
in the brain, helping to regulate key functions in the nervous system.
Research has shown a link between the endocannabinoid system and neurological
disorders, such as Parkinson’s disease, where patients have
been identified to have higher levels of endocannabinoids in their
blood compared to healthy individuals.^71,72^ PILs were
synthesized using the 1-vinyl-3-hexylimidazolium chloride [C6VIm^+^][Cl^–^], 1-vinyl-3-hexadecylimidazolium
bromide [C16VIm^+^][Br^–^] IL
monomers and the 1,10-di(3-vinylimidazolium)decane dibromide [(VIm)2C10^+^][Br^–^]2 IL cross-linker via in situ thermal-initiated polymerization
in a fused silica capillary column to effectively enrich eCBs due
to nonspecific dispersive interactions and the IL hydrogen-bond basicity.
More recently, Souza et al. reported a study on a new cross-linked
zwitterionic PIL coating for fiber-in-tube SPME, which merges the
features of fiber and in-tube SPME.^73^ A
schematic of this setup is shown in Figure 2. A zwitterionic PIL sorbent synthesized
from the 1-vinyl-3-(propanesulfonate)imidazolium ([VIm^+^C4SO3^–^]) IL and the 1,12-di(3-vinylimidazolium)dodecane
dibromide ([(VIm)2C12^+^][Br^–^]2) IL cross-linker was coated on nitinol wires and packed
into a polyether ether ketone capillary to obtain fiber-in-tube SPME.
This setup was used to preconcentrate amyloid β-peptides (Aβs),
biomarkers of Alzheimer’s disease in artificial samples, followed
by quantification using UHPLC-MS/MS for protein binding studies. The
zwitterionic PIL coating enabled preconcentration through ion-exchange
and dispersive interactions. The authors also demonstrated the direct
coupling of the developed fiber-in-tube SPME with MS/MS, allowing
for sensitive detection of Aβ peptides at trace levels in cerebrospinal
fluid samples without the need for chromatographic separation.^73^

Thin film microextraction (TFME), a methodology similar to SPME, has also been explored in different ways using PILs for MEs. This technique improves the surface area-to-volume ratio of the sorbent coating, leading to enhanced mass transfer kinetics and faster extraction equilibration compared to SPME.^58^ Shahriman et al. reported a study where they developed a paper-based TFME approach by grafting the PIL (poly(methyl methacrylateIL)) on the surface of commercial filter paper by using a dipping method to extract sulfonamides in environmental water samples.^74^ The IL monomer used was 1-vinyl-3-hexylimidazolium bromide and the new method proved to be faster, more cost-effective, and simpler than previous techniques for determining sulfonamides in environmental samples, achieving low limits of detection (LOD) and small relative standard deviation values. However, the device’s reusability is limited due to potential leaching of the extractive phase, an issue that will likely be addressed in future design improvements. TFME has also been applied for rapid DNA isolation and recovery in downstream amplification assays. Eitzmann et al. developed reusable TFME devices coated with PILs and demonstrated efficient DNA extraction and compatibility with quantitative polymerase chain reaction (qPCR) analysis.^58^ These devices enable quicker DNA recovery with less harmful solutions for qPCR and loop-mediated isothermal amplification (LAMP). Using a customized LAMP assay, TFME achieved 100% positive detection of a SARS-CoV-2 DNA sequence in artificial oral fluid samples, compared to 66.7% with SPME at a clinically relevant DNA concentration levels.
Microextraction by packed sorbent (MEPS), a miniaturized
format
of SPE, is another form of sorbent ME that has also been used in several
innovative ways with ILs and other subclasses of ILs. Its configuration
employs a sorbent-packed syringe instead of a typical cartridge that
typically reduces solvent usage, simplifies the overall workflow,
minimizes errors, and generates much less waste.^60,61^ Jordan-Sinisterra et al. demonstrated the potential of MEPS when
combined with ILs and their subclasses using the 1-vinyl-3-(butanesulfonate)imidazolium
([Vim^+^C4SO3^–^])
ZIL supported on silica functionalized with graphene oxide via covalent
bonding, as a sorbent for the extraction of pesticides from Brazilian
coffee samples.^61^ The same ZIL supported
on silica was employed to extract polycyclic aromatic hydrocarbons
(PAHs) from coffee samples from both Colombia and Brazil. This approach
not only facilitated the detection and quantification of harmful PAHs
but also demonstrated the durability of the packed MEPS device, which
could be reused over 100 times without compromising its extraction
efficiency. These studies highlight the versatility and effectiveness
of MEPS in combination with ILs for analyzing complex food matrices.^60^
PIL-based SPME coatings have shown wide applicability across various fields. However, the current reliance on manual coating methods presents obstacles to large-scale production. The key challenge lies in achieving high-throughput fabrication of PIL-coated fibers with consistent extraction efficiency, as ensuring uniform and customizable coating thickness across numerous fibers remains difficult. To address this, Hsieh et al. modified a commercial resin 3D printer to reduce prepolymer material usage in the production of sorbent-based extraction devices. Using this innovative platform, two imidazolium-based IL monomers were successfully printed in blade-type geometries for TFME and fiber-type geometries for SPME. Images of the 3D printed TFME blades are shown in Figure 3. The SPME PIL sorbents were applied to extract a variety of organic contaminants, including plasticizers, antimicrobial agents, UV filters, and pesticides from water, followed by HPLC analysis.^75^ The results showed consistent extraction efficiencies across all sorbents with no significant differences in performance, demonstrating the potential of this technique to enhance the functionality and scalability of IL applications in environmental monitoring and analytical chemistry.
![Figure 3: Photographs of the miniaturized printing platform, modified
for
a liquid-crystal display 3D printer and used to create PIL thin film
blades. (a) A thin film blade, measuring 15 mm × 2.5 mm ×
0.5 mm, prepared from a 1 mL mixture of 50% (w/w) [C8Vim^+^][Br^–^], 47% (w/w) diurethane dimethacrylate
(DUDMA) cross-linker, and 3% (w/w) diphenyl(2,4,6-trimethylbenzyl)phosphine
(TPO) photoinitiator. (b) Simultaneous printing using two miniaturized
platforms and two mL volume resin tanks. (c) Depiction of batch printing
achieved during a single print period for blade and fiber geometries.
Ten blades and 12 fibers consisting of PIL sorbents were simultaneously
printed on their respective platforms. Reproduced from Hsieh, S.;
Shamsaei, D.; Ocaña-Rios, I.; Anderson, J. L. Batch Scale Production
of 3D Printed Extraction Sorbents using a Low-Cost Modification to
a Desktop Printer. Anal. Chem. 2023, 95, 13417–13422 (ref (75)). Copyright 2023 American
Chemical Society.](ac5c00264_0003.jpg)
(CPME)
CPME is a ME technique that offers an alternative to traditional sample preparation approaches designed to address the need for a device capable of withstanding complex matrices without damage to the sorbent coating while allowing for easy retrieval and seamless integration with analytical instrumentation.^76^ The extraction process relies on ME capsules composed of the following three key a sol–gel hybrid sorbent embedded in a porous polypropylene capillary membrane, porous polypropylene membranes, and a cylindrical magnet. The capsules are formed by welding two porous polypropylene capillary tubes, with one housing the magnet and the other containing the sorbent. The magnet allows the capsule to spin on a magnetic stirrer while the porous membrane functions as a built-in filtration system, eliminating the need for sample pretreatment like filtration or protein precipitation.^77^ Manousi et al. developed a device incorporating an IL/Carbowax 20M-functionalized sol–gel sorbent into the lumen of porous polypropylene tube^78^ and was employed for the extraction of three phosphodiesterase-5 inhibitors from human serum and urine followed by LC-MS analysis. Given their widespread presence in both legitimate and illicit products, there is a critical need to monitor these compounds in complex matrices such as biological and food samples. To enhance the sorbent’s selectivity, the N-dodecyl-N,N-dimethyl-3-ammonio-1-propanesulfonate ZIL was incorporated to facilitate ion-dipole interactions with the target analytes. The device demonstrated remarkable reusability as it could be reused 25 times for both urine and serum samples. The proposed method was also evaluated for its green characteristics, where it exhibited reduced solvent use, minimal waste generation, cost-efficiency, and operational simplicity. Ntorkou et al. employed a similar strategy in developing a CPME device coupled with LC-post column derivatization for the determination of lanreotide (LAN), a somatostatin analogue, in human urine.^78^ LAN is widely used to treat acromegaly and alleviate symptoms of neuroendocrine tumors.^79^ Since LAN can be detected in the body for at least 11 days following administration, monitoring its distribution during therapy is crucial for assessing treatment effectiveness. The device incorporated a sol–gel Carbowax 20M-ZIL composite sorbent and the 3-[benzyl (dimethyl) ammonio]propane-1-sulfonate ZIL to enhance the extraction recovery of LAN by facilitating π–π interactions and ion-dipole interactions.
Systems (ABS) Using ILs
ABSs are widely
utilized for the separation, purification, extraction, and enrichment
of various biomolecules including proteins, animal cells, nucleic
acids, and pharmaceuticals.^80^ ABSs are
liquid–liquid systems formed by mixing at least two water-soluble
components. When these components exceed certain concentrations under
specific temperature and pH conditions, they separate into two immiscible
phases.^81^ Depending on the system, ABSs
can be created using polymer–polymer, polymer-salt, or salt–salt
mixtures dissolved in an aqueous medium.^82^ Extractions are largely driven by either the salting-out process
or interactions between hydrophobic and hydrophilic regions within
the polymer’s micellar framework.^83^ Traditional polymer-based ABSs offer a narrow polarity range between
their coexisting phases, which limits their ability to achieve high
extraction efficiency and selectivity in a single step. This limitation
can be addressed by incorporating ILs as phase-forming components
in ABSs, thereby enabling improved performance. González-Martin
et al. reported a study where an IL-based ABS system was employed
as a one-step platform for cleanup, ME, and preconcentration of bisphenols
as representative salivary biomarkers for their improved determination.^81^ In this study, a miniaturized ABS system was
developed using the low cytotoxic butylguanidinium chloride ([C4Gu**^+^][Cl^-^**]) IL and dipotassium phosphate
as the salting-out agent. Bisphenols were selected as salivary biomarkers
due to their growing endocrine-disrupting effects. Sample cleanup
was achieved by precipitating most of the interfering salivary proteins
into a protein-enriched solid interphase of the ABS, while extraction
and preconcentration of bisphenols were achieved in the IL-rich phase.
Bisphenols were then determined using HPLC and fluorescence detection
and the method obtained higher green scores when evaluated for different
greenness metrics. Similarly, Ferreira et al. reported ABS systems
composed of cholinium-based ILs and polypropylene glycol 400 to pretreat
human serum for isolating E. coli genomic DNA from
human serum albumin (HSA), thereby minimizing interference in DNA
quantification by real-time PCR.^82^ The
pretreatment was carried out at different pH values, revealing that
HSA precipitated under low pH conditions, while no precipitation occurred
at neutral pH. The most effective system used cholinium glycolate
at pH 5, which resulted in complete HSA precipitation at the ABS interface
while the IL-rich phase was enriched with high purity stable DNA.
This IL-based ABS offered an effective way to prepare human serum
samples, enabling the isolation of bacterial DNA and improving bacterial
infection monitoring.
Flora et al. utilized an IL-based ABS
coupled to a bead-based microfluidic immunofluorescent assay to extract
and detect prostate-specific antigens from human serum.^84^ The tetrabutylammonium chloride [N4444^+^][Cl**^-^] and tetrabutylphosphonium bromide
[P4444^+^][Br^-^]-based ABSs with phosphate
buffer demonstrated reduced background fluorescence from interfering
matrix components, and higher enrichment of the antigens into the
IL-rich phase allowed for an LOD of 4.9–5.1 ng mL^–1^ compared to the PEG (molecular weight 1000 g mol^–1^)-ABS system with citrate buffer reaching 12.3 ng mL^–1^. A very recent study by Phakoukaki et al. reported an innovative
approach by combining IL-based ABS systems with small channels for
continuous plug-flow extraction of l-tryptophan, showcasing
the potential of ABS technology in diverse applications.^85^ This method extracted l-tryptophan
using channels with internal diameters of 0.5 mm and 0.8 mm, employing
different IL-ABS formulations composed of varying wt % of the [C4MIm^+^][Cl^-^**] IL and potassium phosphate.
The extractions were performed under plug flow conditions, where fluid
moves in separate plugs without much mixing. Higher concentrations
of salt and IL improved the partitioning of the amino acid into the
IL-rich phase. Overall, the mass transfer rates in this system were
significantly faster than those in traditional solvent extraction
methods making it highly efficient.
(GC)
GC is an analytical technique that separates volatile and semivolatile compounds based on their affinities for a stationary phase. Current commercial GC phases often have difficulty in separating highly basic or acidic compounds with acceptable peak symmetry and provide low chromatographic resolution for samples with a wide range of functional groups. Recently, there has been an increase in the utilization of ILs as chromatographic stationary phases due to their distinct properties. ILs possess unique and tunable selectivity, low vapor pressure, and high thermal stability and are advantageous for use in GC, as they separate a wide range of analytes with different functionality, can be utilized at high oven temperatures, and provide high separation efficiencies.^86,87^ ILs are capable of separating both polar and nonpolar molecules through simultaneous dipolar interactions, electrostatic interactions, hydrogen bonding, and dispersion interactions that can be tuned by modifying their chemical structure. These advantages have led to an increased interest in ILs as stationary phases in GC.^87^
One application in which ILs
are utilized in GC is as stationary phases for microfabricated columns.
Microfabricated columns are typically used in μGC, which is
a miniaturized form of GC that utilizes short columns, allowing for
portable, in-field separations and short analysis times. However,
the separation power becomes limited as the length of μGC columns
are decreased, requiring new and highly selective stationary phases.
Gholizadeh et al. developed a new column configuration, shown in Figure 4, utilizing three,
30 cm long semipacked GC columns with IL stationary phases in tandem
to maximize separation performance.^88^ In
this work, the following three ILs were 1-butylpyridinum
[NTf2^–^] (IL1), 1-(2-hydroxyethyl)-3-methylimidazolium
[NTf2^–^] (IL2), and methyltrioctylammonium
[NTf2^–^] (IL3). The IL stationary phases
were designed for increased analyte selectivity in a mixture consisting
of (1) saturated alkanes (C7–C30), (2)
analytes with boiling points ranging from 80 to 238 °C, and (3)
analytes with varying degrees of polarity. While none of the columns
separated all components of the 46-compound mixture, complete separation
of all analytes was achieved when the three IL columns were placed
in a parallel configuration (i.e., IL1 v. IL2, IL2 v. IL3, and IL1
v. IL3), wherein the columns behaved as a pseudo-2D GC method. By
adding the IL2 column as a second dimension to the IL1 column in a
parallel configuration, previously coeluting compounds (pentanone
and ethylbenzene) were separated. Using the method, a 46-compound
mixture was fully separated within 4 min, ultimately preserving the
short analysis times of μGC. Similarly, Meziani et al. introduced
the use of a GC column with radially elongated pillars as a second
column in GC × μGC.^89^ This column
was statically coated with a medium polarity IL based on a monocationic
phosphonium derivative and a Supelco Equity-1 (OV-1701) column was
used for the first dimension. Lower theoretical plate heights were
achieved for the μGC column containing the IL stationary phase
compared to other prepared columns, except for the polydimethylsiloxane
(PDMS) column of similar film thickness. However, the 2D system was
able to effectively separate alkanes and aromatics, though better
separation was achieved using a PDMS stationary phase. Interestingly,
a reversal of elution order was observed for the polar polyethylene
glycol (PEG) and midpolar IL stationary phases tested compared to
PDMS, in which alkanes were less retained. Issues concerning wrap-around
were also noted, but further reduction in the column length was hypothesized
to solve this problem.
![Figure 4: SEM images show (A) the top view of semipacked μGC
column
(200 μm scale), (B) a zoomed-in view of the silicon micropillars
and channel (150 μm scale), (C) a cross view of pillar coated
with [C4Pyr^+^][NTf2^–^] IL (16 μm scale), and (D) a magnified view of the uniform
IL coating on a micropillar (3 μm scale). Golay plots (E) for
[C4Pyr^+^][NTf2^–^],
[C2OHMIm^+^][NTf2^–^], and [N1888^+^][NTf2^–^] IL are shown under the following injection volume,
0.1 μL; split ratio, 1; inlet temperature, 280 °C;
detector temperature, 300 °C; and oven temperature, 100 °C.
Reproduced from Gholizadeh, A.; Chowdhury, M.; Agah, M. Parallel Ionic
Liquid Semi-Packed Microfabricated Columns for Complex Gas Analysis.
Anal. Chem. 2020, 92, 10635–10642 (ref (88)). Copyright 2020 American
Chemical Society.](ac5c00264_0004.jpg)
Traditional GC stationary phases, such as PDMS or PEG, are susceptible to hydrolysis and oxidation when less expensive, nonultra-high purity carrier gases are used, which can lead to higher column bleed, increased peak broadening and tailing, and stationary phase deterioration.^87^ To combat these issues, Li et al. used phosphonium ILs as μGC stationary phases to decrease stationary phase moisture and oxygen uptake, thereby increasing the separation performance.^90^ By coating a chip-based IL column, they were able to completely separate polar and nonpolar compounds, such as mixtures of alcohols, fatty acid methyl esters (FAMEs), chloroalkanes, alkanes, and aromatics. To verify the ILs’ resilience to hydrolysis and oxidation, the prepared columns were then exposed to moisture and oxygen, where they showed high stability when comparing retention times and full-width half maximums of peaks between the dry injections and moisture injections, indicating low stationary phase degradation. While only phosphonium-based ILs were studied, the authors noted that other ILs could be introduced for more specific and selective separations.
A new μGC stationary phase was introduced by Bae et al. consisting
of the [C4MIm^+^] tetrafluoroborate [BF4^–^] and dimethylpolysiloxane incorporated into a
3 m long hybrid gel microcolumn for the identification of narcotic
substances.^91^ The IL-based hybrid gel microcolumn
was able to separate eight volatile organic compounds and seven narcotic
substance mixtures with high column efficiency and temperatures up
to 240 °C. Volatile organic compounds were separated due to increased
π–π interactions and hydrogen bonding compared
to a pure dimethylpolysiloxane reference column. For the narcotic
substances, the prepared column was shown to increase the retention
times for ketamine, cocaine, and 3,4-methylenedioxymethamphetamine
compared to the reference dimethylpolysiloxane column due to increased
π–π interactions, ion-dipole interactions, and
ion-induced interactions in the prepared hybrid gel column. Additionally,
the prepared hybrid gel column showed increased column efficiency
and decreased peak tailing compared to the dimethylpolysiloxane column,
overall proving to be more effective in the separation of drug molecules.
Patrushev et al. reported for the first time ILs as stationary
phases for multicapillary columns in traditional GC, providing short
analysis times and operation over a wide range of flow rates.^92^ These multicapillary columns consisted as packs
of 1,375 capillary columns that were 40 μm in diameter and a
length of 23 cm. The high number of capillaries allows for multicapillary
columns to be able to withstand high sample loading, while also being
able to utilize high flow rates and high separation speeds. The prepared
columns were coated with the 1,2-dimethyl-3-propylimidazolium ([C3M(M)Im*^+^]) [NTf2^–^], 4-methyl-N-propylpryidinium ([C3MPyr^+^]) [NTf2^–^], and 6-methyl-N-hexylquinolinium ([C6MQu^+^]) [NTf2^–^] ILs. van Deemter plots were generated
for the three stationary phases in which the [C3MPyr^+^][NTf2^–^] IL showed the lowest theoretical plate heights at higher
flow rates and the [C6MQu^+^][NTf2^–^] showed the lowest efficiencies
at higher flow rates. The [C3MPyr^+^][NTf2^–^*] IL separated
seven dimethylphenols within 45 s, and C16–C24 FAMEs within 75 s.
Liquid Stationary Phases
In recent years, there has been increased research where ILs have been added to structurally rigid macrocyclic molecules for chromatographic analysis of structurally similar isomers, including alkyl benzenes, halogenated benzenes, anilines, and phenols.^93^ The three-dimensional structure introduces cavities in which analytes are able to enter and interact with the IL-functionalized sites of the molecule, allowing for stronger interactions and higher selectivity. Yu et al. presented an IL GC stationary phase consisting of two imidazolium cations attached to a triptycene (TP) framework.^94^ TP has a three-dimensional structure consisting of three benzene rings and three open π-electron rich cavities, allowing for high thermal stability and multiple sites for functionalization.^93,94^ This stationary phase was shown to baseline resolve anilines and phenols as well as positional isomers with good peak symmetry–a task otherwise hard to accomplish.^94^ The new structure allows for a synergistic effect of multiple molecular interactions involving hydrogen bonding, dipole–dipole, cation-π/anion-π, and π–π stacking interactions originating from the unique amphiphilic structure. He et al. also introduced a TP-based stationary phase by combing the rigid backbone of the TP with three flexible octyl-imidazolium side chains to increase selectivity of analytes with high similarity.^93^ The stationary phase achieved higher resolution of critical m-/p-halobenzene compounds, acidic and basic isomers, and showed selectivity for polar molecules.
Yuan and Qi created a new form of a TP-based IL stationary phase
by bonding it to a dicationic ionic liquid (DIL).^95^ The addition of a guanidinium (G) DIL provided higher selectivity
toward a range of positional and structural isomers. The TPG stationary
phase separated mixtures of phenols, anilines, and weakly polar aromatic
isomers with high resolution, showing that the amphiphilic selectivity
of the TPG column results from the triptycene framework and the guanidinium
cations. In addition, the steric hindrance introduced by the triptycene
moiety produced intermolecular space that provided easier access to
isomers with relatively less molecular volume, leading to the different
retention of the alkane isomers and pentanol. In a separation of mint
essential oils, the TPG column was able to resolve 30 components,
12 more than the reference DB-35MS column with (35% phenyl)methyl
polysiloxane as the stationary phase, indicating higher selectivity
and separation capability. Similar to the aforementioned studies,
Ba et al. introduced a novel GC stationary phase framework in which
they attached an octyl-imidazolium [NTf2^–^] IL with a C4 linker to a pillar[6]arene, a complex with
12 available sites for functionalization and π-electron-rich
cavities.^96^ In this study, the prepared
column was found to differentiate between phenol, aniline, aldehyde,
alkane, and aromatic isomers, as well as cis-/trans- isomers. The excellent resolving performance is attributed
to the comprehensive interactions of the rigid three-dimensional structure
of the pillar[6]arene, providing interactions with the aromatic cavities
and the polar imidazolium ILs. The above studies clearly indicate
that introducing ILs into rigid, three-dimensional structures enhance
the selectivity and resolution of otherwise hard to separate isomers
when applied as stationary phases in GC.
Thermal Stability
GC utilizes
high temperatures for separation and elution of analytes; therefore,
thermally stable stationary phases are required. Phosphonium IL-based
stationary phases exhibit lower maximum allowable operating temperatures
(MAOTs) in the range of 180–200 °C, which limits their
use as routine GC stationary phases.^86^ Cagliero
et al. studied the influence of immobilization of phosphonium-based
IL stationary phases on the MAOT of the column.^86^ By immobilizing the stationary phase to the inner wall
of the capillary using a proprietary method, an overall increase in
the MAOT was observed. In addition, when compared to the same stationary
phase that was not bonded, the immobilized phosphonium IL-based stationary
phase presented a negligible difference in selectivity, indicating
that the interaction mechanism is maintained after immobilization.
Another method for increasing the thermal stability of IL-based GC
stationary phases was introduced by Odugbesi et al. and described
perarylated ILs consisting of sulfonium and phosphonium cations with
the [NTf2^–^] anion.^97^ Perarylated ILs are much less susceptible toward undergoing
Hofmann elimination (particularly with weakly nucleophilic anions),
making them much more thermally stable. Unlike columns reported by
Cagliero et al., these stationary phases were not immobilized to the
capillary wall and provided MAOTs of 290–350 °C with improved
selectivity for heavier polycyclic aromatic hydrocarbons.
of Fragrance and Oil Mixtures
While the
above studies provide a small introduction into IL applications in
GC, a prominent area of interest is the use of ILs in the separation
of fragrance and oil mixtures. Fragrances and oils consist of complex
mixtures of structurally similar compounds, making their separation
difficult and many contain environmental pollutants that are challenging
to quantify due to mixture complexity. New stationary phases with
unique selectivity are of great interest in the fragrance and oil
field due to the large number of analytes consisting of a wide range
of functional groups, making ILs promising stationary phases for their
analysis due to their tunable chemical structures.^98^ Mazzucotelli et al. investigated the effect of the anion
on separation selectivity for phosphonium-based ILs.^98^ For the separation of both sage and vetiver essential oils,
the IL stationary phase with [Cl^–^] anions separated
monoterpenoid and sesquiterpenoids based on functional groups, separating
ketones, esters, and alcohols sequentially. The IL stationary phase
with [NTf2^–^] anions did not separate
the components based on functional groups but instead separated monoterpenoid
hydrocarbons from sesquiterpenoids and oxygenated compounds as a function
of analyte polarity and volatility. Crucello et al. proposed a new
method for the separation and quantification of polychlorinated biphenyls
in insulating oils using two-dimensional GC (GC × GC).^99^ GC × GC is a chromatographic method that
combines two capillary columns featuring complementary selectivity
for highly effective separations. In this method, the commercially
available IL column SLB-IL59, consisting of the ditripropylphosphonium)dodecane
([(P3,3,3)2C12^+^]) [NTf2^–^] IL allowed for rapid elution of aliphatic
hydrocarbons due to low dispersive interactions as well as dipole–dipole
interactions, thereby increasing retention of aromatic hydrocarbons.
Using the SLB-IL59 column, a sample preparation step that is typically
required for the analysis of biphenyls could be eliminated and lower
pressures could be utilized to promote overall greener analysis. Additionally,
Nan et al. provided a first look into the use of imidazolium-based
ZILs possessing sulfonate anions as stationary phases for the separation
of volatile carboxylic acids (VCAs) in GC.^28^ VCAs are important molecules in the pharmaceutical and flavor and
fragrance industries,^100^ but are difficult
to quantify as they tend to hydrogen bond with exposed silanol groups
on the surface of fused silica capillary, leading to high peak asymmetry.
ZIL stationary phases provided excellent peak shapes compared to the
commercial column SLB-IL111, consisting of the 1,5-di(2,3-dimethylimidazolium)pentane
([(M(M)Im)2C5^+^]) [NTf2^–^] IL, as well as higher retention and unique selectivity.
The use of ILs in chromatography is a continuously growing field due to their previously mentioned advantageous properties. Their use as HPLC stationary phases and mobile phase additives has given rise to new separation capabilities, providing an overall increase in resolution and selectivity for otherwise hard to separate analytes. IL-modified stationary phases interact with analytes through various mechanisms that can be tailored to favor different modes of separation.^101^ These different modes are dependent on the target analyte, which overall dictates the stationary phase and the employed mobile phase. The most common separation modes include reverse phase liquid chromatography (RP-LC), hydrophilic interaction chromatography (HILIC), and mixed-mode chromatography, all of which will be discussed in this section.
HPLC Stationary Phases and Mobile Phase Additives
Due to
the complex structure with the potential of multiple functionalities
that ILs possess, their use in HPLC focuses on mixed-mode chromatography.
However, there are studies in which ILs have been applied for use
in RP-LC. ILs were introduced as mobile phase additives in HPLC for
the improvement of column efficiency and peak shape due to their ability
to suppress interactions with silanol groups present on the stationary
phase.^102^ Treder et al. exhaustively investigated
the effect of IL functionality as RP-LC mobile phase additives.^102^ In this work, 17 ILs were studied for the separation
of anthracycline antibiotics. It was found that the identity of the
cation did not matter as much as its size with larger cations resulting
in lower retention, due to increased hydrophobicity. In addition,
anions that exhibited low adsorption to the C18 stationary
phase were the best in separating anthracyclines, and the retention
mechanism of anthracyclines could be controlled to improve the separation.
In a separate study, Treder et al. investigated the use of ILs as
mobile phase additives when aromatic stationary phases were employed.^103^ They studied the effect of anion identity with
imidazolium and pyridinium cations for 13 different ILs in the separation
performance of anthracyclines. With the aromatic stationary phases,
π–π interactions are possible with the aromatic
anthracyclines compared to the previously studied C18 stationary
phase, thereby promoting increased retention. Interestingly, they
found that the addition of an IL into the mobile phase reduced retention
of anthracycline antibiotics on the aromatic stationary phases compared
to the C18 stationary phase. Specifically, anthracycline
retention decreased in the order of [PF6^–^] > [CF3SO4^–^] > [BF4^–^] > [CH3SO4^–^] > [Cl^–^] for each stationary
phase. This effect
was ascribed to the ability of the IL additives to undergo π–π
interactions with the anthracycline analytes, thus decreasing the
π–π interactions with the stationary phase.
Tereba-Mamani et al. introduced a new RP-LC mobile phase consisting
entirely of sodium dodecyl sulfate (SDS) and 1-ethyl-3-methylimidazolium
[C2C1IM^+^] [Cl^–^],
1-butyl-3-methylimidazolium [C4C1Im^+^] [Cl^–^], and 1-hexyl-3-methylimidazolium [C6C1IM^+^] [Cl^–^], utilizing
no organic solvent for the separation of basic analytes.^104^ The mobile phase allowed for basic compounds
to be attracted to the anionic portion of SDS while being repelled
by the IL cation, which allows for modulation of retention with varying
IL/SDS concentration. This mobile phase was applied in the separation
of β-adrenoceptor antagonists; high retention was obtained with
SDS and the IL individually and modulated when both were present.
While ILs were originally introduced as mobile phase additives
in RP-LC, IL research has expanded into their use as stationary phases.^102,105^ Jiang et al. functionalized carbon dots with 1-vinyl-3-octadecylimidazolium
[C18VIm^+^] [Br^–^] and grafted
them onto silica, allowing for increased separation of polar analytes.^106^ Carbon dots exhibit high stability, low toxicity,
biocompatibility, and modifiability.^106^ The prepared Sil-ImC18/carbon dot stationary phase separated
alkyl benzenes, PAHs, aromatic amines, and phenols.
Phases for Hydrophilic Interaction Chromatography (HILIC)
HILIC is a HPLC mode that typically utilizes a high proportion of acetonitrile (ACN) to water as the mobile phase for the separation of polar and hydrophilic compounds.^107^ It is hypothesized that HILIC operates by creating a stagnant water layer around the polar stationary phase, into which the polar and hydrophilic analytes partition before interacting with the stationary phase. Similar to the work completed by Jiang et al., Song et al. introduced imidazolium IL-derived carbon dots grafted to silica for use as a stationary phase in HILIC mode.^108^ The prepared column, referred to as Sil-ImCDs, exhibited higher hydrophilic interactions compared to an imidazolium IL-functionalized stationary phase and an aminopropyl silica stationary phase. In addition, the prepared stationary phase exhibited decreased peak tailing and increased column efficiency, all of which were ascribed to the imidazolium, carboxyl acid, and hydroxyl functional groups present on the carbon dots.
Guo et al. investigated the use of imidazolium-based ILs
with a chloride anion as stationary phases for HILIC mode.^109^ In this study, typical compounds such as saccharides,
nucleosides, and nucleobases were used as target analytes. Monosaccharides
exhibited short retention, disaccharides moderate retention, and trisaccharides
high retention, indicating that retention is influenced by the number
of hydroxyl groups present and the polarity of the analytes. Since
mobile phase composition is an important factor in HILIC, the effect
of decreasing the proportion of ACN was investigated. At a 75% ACN
composition, the saccharides could not be resolved, but at 95% ACN
composition, the saccharides were fully resolved at shorter analysis
times compared to a commercial reference column. This study also investigated
the difference of the anion present in the IL, in which [NTf2^–^], [BF4^–^], and [Cl^–^] were utilized. The [Cl^–^] and [BF4^–^] anions exhibited better resolution and
increased retention compared to [NTf2^–^] under the same chromatographic conditions. This effect is ascribed
to the stronger dipoles and induced field strength of ion-pair in
[Cl^–^] and [BF4^–^], leading
to overall stronger interactions with the anions compared to [NTf2^–^].
Mixed-mode chromatography utilizes a single stationary phase capable of providing multiple interaction modes for the separation of highly complex analyte mixtures.^105,110^ These stationary phases are typically amphiphilic to induce hydrophilic and hydrophobic interactions and may possess aromatic moieties to induce π–π interactions. Due to the various interactions possible, mixed-mode chromatography has a high separation power and selectivity for analytes with differing functionality.^105^ These clear advantages make development of mixed-mode stationary phases an important area of research. Luo et al. introduced hydrophilic carbonyldiimidazolium [CDI^+^] [Cl^–^] and hydrophobic dodecyl (DD) together onto the surface of silica for a new mixed-mode stationary phase to improve the separation selectivity of environmental endocrine disruptors, including alkylphenols, bisphenols, phthalates, and steroidal hormones in RP mode.^111^ When separations were performed in RP mode, retention increased as hydrophobicity of the analytes increased, except in the case of bisphenols, whose elution order was independent of hydrophobicity. When separations were performed in HILIC mode, nucleosides and bases were baseline resolved, without the addition of buffer salts to control pH. While this stationary phase was able to separate the hydrophilic nucleosides and nucleobases, it exhibited poor selectivity for other hydrophilic analytes. To overcome this limitation, the same group then introduced a novel imidazolium IL embedded multifunctional stationary phase.^105^ In this IL stationary phase, 1-allyl-3-vinyl-imidazolium was reacted onto thiolated silica gel, which was then reacted further with stearyl thioglycolate to embed the imidazolium moiety. The prepared stationary phase, Sil-AVI-ST, was able to separate hydrophilic sulfonamides, vitamins, and nucleosides and nucleobases as well as hydrophobic phthalates, bisphenols, alkylphenols, and steroid hormones. The observed selectivity was attributed to the imidazolium cations being capable of multiple interactions with the target analytes, as well as the polar vinyl groups imparting increased hydrophilic interactions.
Wang et
al. developed two IL stationary phases consisting of a dicationic
imidazolium cation paired with [NTf2^–^] anions with two (DPE-DIL) and four (BND-DIL) aryl groups for increased
separation selectivity for food additives.^112^ The two prepared stationary phases were able to resolve nucleobases
and nucleosides with low tailing factors when used in HILIC mode,
but provided different elution orders for cytidine and inosine, indicating
different selectivity. Under RPLC mode, the two stationary phases
were able to separate three terphenyl isomers and triphenylene. Again,
differences in selectivity between the two stationary phases were
observed, as m-terphenyl and p-terphenyl
coeluted on the DPE-DIL stationary phase, but were fully resolved
on the BND-DIL stationary phase. Thus, the BND-DIL stationary phase
was utilized for the separation of food additives. Nitrites and nitrates
were able to be detected from different food samples with recoveries
from 96.4 to 103.8%.
Many studies have investigated the effect
of IL cation placement
for mixed-mode stationary phases. One investigation conducted by Fan
et al. studied the effect of spacer alkyl chain length on the retention
of alkylbenzenes, nucleoside bases, and inorganic ions among three
IL stationary phases, Sil-C4Im, Sil-C7Im, and
Sil-C10Im with [NTf2^–^] anions,
under various HPLC modes to mimic mixed-mode conditions.^101^ In RPLC, the selectivity of aromatic molecules
increased as the spacer alkyl chain length between the silica and
the imidazolium cation was increased. Interestingly, the retention
factors increased when the spacer chain length was lengthened from
C4 to C7, but did not increase linearly from
C7 to C10. They hypothesized this to be due
to the C4 and C7 molecules lying flat on the
stationary phase due to shorter spacer alkyl chains resulting in higher
electrostatic attraction between the imidazolium cation and the dissociated
silanol on the silica surface, while the C10 lays in a
vertical state on the stationary phase due to the longer chain shielding
electrostatic attraction and increasing retention. In HILIC mode,
the five nucleoside bases were able to be separated completely in
order of increasing polarity. When employed in anion exchange chromatography
(AEX), the [BrO3^–^], [NO3^–^], [I^–^], and [SCN^–^] compounds were fully separated, with the C10 exhibiting
the highest selectivity due to the longer spacer alkyl chain.
Luo et al. studied three regioisomeric IL silane stationary phases,
in which the position of the imidazolium cation was translated along
the stationary phase moiety; the three stationary phases were referred
to as Sil-C2Im-C8, Sil-C6Im-C4, and Sil-C9Im-C1.^110^ All three stationary phases exhibited retention of hydrophilic
nucleobases under HILIC conditions as well as increased retention
of hydrophobic analytes under RPLC conditions. They found that due
to the long alkyl chain of Sil-C2Im-C8, hydrophilic
interactions between the analytes and the imidazolium cation were
hindered, producing the lowest retention and thus hydrophilicity under
HILIC conditions. Interestingly, the strongest hydrophilicity was
exhibited by Sil-C6Im-C4 as nucleotides were
most strongly retained on this stationary phase. The increased separation
performance of alkyl benzenes and PAHs in RPLC mode was observed when
the imidazolium moiety was embedded on the outermost part of the alkyl
chain, due to an increase in aromatic system accessibility.
A similar study was conducted by Wang et al. investigating the
relative length of two ILs consisting of imidazolium cations and [NTf2^–^] anions and a secondary carboxylic acid
functionalized silane stationary phases on the separation performance
of mixed-mode separations in HPLC.^113^ The
stationary phases, referred to as Sil-C4Im-C9Co and Sil-C9Im-C4Co, were both thought to
retain solutes through hydrophobic, hydrophilic, ion-exchange, and
π–π stacking interactions. The study found that
the anion strength was greater for Sil-C9Im-C4Co, as evidenced by the higher retention times of acids, whereas
the Sil-C4Im-C9Co stationary phase offered higher
retention of amines. In addition, under RPLC conditions, Sil-C9Im-C4Co completely resolved five alkylbenzenes
and four PAHs, which was not observed for the Sil-C4Im-C9Co stationary phase and indicates a difference in hydrophobicity
based on cation location.
In addition to an investigation of cation placement and alkyl chain length, the bonding of ILs to nontraditional silica particles or nonsilica particles has also been investigated. These materials are typically resistant to acid and base and allow for even functionalization, as well as decreasing silanol interactions for nontraditional silica particles.^107^ Chen et al. introduced gold nanoparticles (NPs) that were covalently bonded to an IL bridged periodic mesoporous organosilica (PMO) stationary phase for per aqueous liquid chromatography (PALC).^107^ PALC separates polar compounds using a high proportion of water, typically consisting of 90% or more as the mobile phase, making it an overall greener separation technique compared to HILIC. The prepared PMO-ILs-Au NPs column was studied under various modes to investigate the separation capability. In HILIC, the PMO-ILs-Au NP stationary phase increased retention of polar molecules as the mobile phase polarity was decreased, indicating a typical HILIC retention mechanism. When using 80/20 water/ACN as the mobile phase in PALC, no significant differences in analyte retention factor or peak shape were observed compared to HILIC with a 10/90 water/ACN mobile phase, indicating that this stationary phase in PALC could be used as a new chromatographic separation mode for the separation of polar molecules. From this finding, the authors then utilized PALC mode for detection and recovery of eight biogenic amines, in which recoveries of the method ranged from 63.52 to 93.08%. PALC mode was determined to be a simple, accurate, and rapid method complementary to RPLC and an alternative to HILIC that is capable of effectively separating polar analytes.
PILs have also increased in popularity due to their increased column stability under a wide range of chromatographic conditions. Liu et al. introduced a new classification of stationary phase for the mixed-mode separation of phospholipids by polymerizing phosphonium ILs onto silica microspheres.^114^ Structurally, phosphonium-based ILs and phospholipids are similar as they both contain a charged, hydrophilic phosphorus headgroup and hydrophobic alkyl chains, allowing for excellent separation selectivity of phospholipids. In preliminary studies, the stationary phase exhibited both hydrophilic and hydrophobic separation capabilities. Due to the strong hydrophobicity of the stationary phase and similar structure to phospholipids, excellent separation selectivity for phospholipid classes compared to a commercial amino column was achieved. Peng et al. prepared polymeric IL microspheres as HPLC stationary phases for separations in mixed-mode chromatography.^115^ PIL microspheres were determined to provide high surface area, allowing for increased interaction sites, as well as stationary phase stability. The monodisperse microspheres separated mixtures of alkylbenzenes, nucleosides, and alkaloids in RPLC and HILIC mode. In HILIC specifically, uracil and cytosine were able to be separated effectively in pure water, allowing for greener separations with the use of the prepared PIL microspheres.
HPLC is often
employed in the separation of biological compounds,
which may be chiral. Chiral chromatography is often used to separate
enantiomers and utilizes silica particles functionalized with a chiral
selector, such as cyclodextrin (CD).^116^ The separation of enantiomers is important as many biological and
drug molecules are made up of enantiomers that have different chemical
properties. Zhou et al. functionalized a C18 stationary
phase with the 3-n-octadecyl-1-vinylimidazolium bromide IL and 6-(1-allylimidazolium)-cyclodextrin
tosylate monomers as a mixed-mode stationary phase for achiral and
chiral separations.^116^ The stationary phase
separated PAHs, alkylbenzenes, and terphenyls completely in RPLC as
well as nucleosides and nucleotides in HILIC mode with better peak
shapes and shorter separation times compared to a commercial ZORBAX
NH2 column. In ion-exchange chromatography (IEC), the stationary
phase was also able to separate benzoic acids and phenols. For use
in chiral separations, the β-CD functionalized IL stationary
phase was able to separate enantiomers of 1-phenylpropanol, warfarin,
and styrene oxide through anionic exchange interactions. Another study
attached an imidazolium IL functionalized poly(quinine) to silica
as a mixed-mode stationary phase.^117^ By
combining quinine with imidazolium ILs in a chromatographic separation,
aromatic compounds were completely separated in IEC, sulfanilamides,
nucleosides, and nucleobases were separated in HILIC, and alkylbenzenes,
benzene, and PAHs were separated in RPLC. In addition, quinine is
an excellent chiral selector that resulted in the separation of three
pairs of enantiomers with high selectivity. This stationary phase
overall exhibited dipole–dipole, hydrophilic, anion-exchange,
and chiral separation capabilities.
ILs have also been applied as part of monolithic stationary phases in capillary columns.^118^ Unlike traditional HPLC column consisting of packed silica particles, monolith columns consist of connected silica or polymer skeletons that provide good permeability and lower backpressures compared to traditional packed HPLC columns.^119^ As a result, they provide fast mass transfer and high permeability, making their application promising for the development of HPLC stationary phases.^120^ Moravcová et al. introduced a monolith rod modified with a phosphonium-based IL for use in capillary liquid chromatography.^118^ The prepared stationary phase, trioctyl(3/4-vinylbenzyl)phosphonium chloride, was found to exhibit mixed-mode interactions, including hydrophobic, hydrophilic, and electrostatic interactions, allowing high separation and selectivity for compounds with differing substitution patterns on alkylbenzenes, functionalities, and different groups of analytes.
Polyhedral oligomeric silsesquioxane (POSS) is an easy to modify, three-dimensional structure and is robust to a wide pH and temperature range, making POSS ideal for chromatography. By introducing an IL to the POSS structure, multiple interaction mechanisms, including π–π, ion exchange, hydrophobicity, hydrophilicity, and hydrogen bonding can be achieved. Chen et al. introduced an allyl vinyl imidazolium (AVI) and D-2-allylglycine (AG) functionalized POSS monolithic column for the separation of phenols, alkylbenzenes, aromatic amines, nucleobases, amides, and thioureas.^120^ Alkylbenzenes, amines, and phenols were separated through the RPLC retention mechanism and an increase in retention as the hydrophobicity of the alkylbenzene increased was observed. Nucleobases, amides, and thioureas were baseline resolved through HILIC retention mechanisms, and provided high separation efficiencies. The prepared column was then utilized to successfully separate cytochrome c tryptic digests and egg white protein extraction, indicating a promising future in the separation of macromolecules. Similarly, Zhou et al. functionalized a POSS methacryl substituted (POSS-MA) with 1-vinyl-3-dodecylimidazolium bromide (VDI) to form a POSS-VDI monolithic column.^121^ Alkylbenzenes were able to be separated through the RPLC retention mechanism with analysis times under 8 min, high efficiencies, and tailing factors not exceeding 1.29. Hydrophilic analytes, such as thioureas, were baseline separated within 5.5 min and achieved high separation efficiency, showing that POSS-VDI separated both hydrophobic and hydrophilic analytes. Furthermore, the separation of Fangji and the Roots of Kudzu Vine components was achieved for active ingredient identification.
Separation
technologies often involve methods like crystallization,
fractional distillation, solvent extraction, and chromatography, which
can be complex, energy consuming, and lead to high solvent waste.^122^ To address these issues, more advanced and
efficient techniques have been developed utilizing membrane-based
approaches. A membrane is a thin layer that separates substances according
to their physical and chemical characteristics when subjected to a
driving force, such as a gradient in chemical potential (either concentration
or pressure) or electrical potential.^123^ A membrane can be homogeneous or heterogeneous, symmetric or asymmetric,
and can take the form of a solid or liquid made from organic or inorganic
materials. It may be neutral or charged and can contain functional
groups for specific binding or complexing.^124^ In recent years, separation via liquid membrane (LM) has become
popular and valuable in fields like biotechnology, organic chemistry,
chemical engineering, and wastewater treatment. A LM consists of a
thin, uniform, nonporous layer of organic liquid positioned between
two aqueous or gas phases of different compositions.^125^ Generally, LMs are categorized into two supported
and nonsupported. Nonsupported LMs include emulsion liquid membranes
(ELMs) and bulk liquid membranes (BLMs), while supported LMs include
hollow fiber and flat sheet configurations and are stabilized by capillary
forces within the pores of polymeric or inorganic films. The field
of membrane separation is vast, and extensive research has been conducted
in this area. Although much of the focus has been on CO2 capture, membrane separation has also been applied in wastewater
treatment,^126^ removal of toxic pollutants,^127^ heavy metal separation,^128^ and biofuel recovery,^129^ among
other applications.
As concerns
about global warming
and rising carbon dioxide (CO2) emissions from fossil fuels
continue to grow, research into CO2 capture has gained
significant attention.^130,131^ CO2 is
emitted in the form of various mixtures, including CO2/N2, CO2/CO/N2, CO2/CO/H2, and CO2/CH4. CO2 capture
is generally categorized into three main precombustion capture
(CO2/H2), postcombustion capture (CO2/N2), and oxygen-enriched combustion (O2/N2). Compared to precombustion and oxy-combustion methods, postcombustion
CO2 capture offers significant advantages due to its ease
of operation and compatibility with existing production processes.^132^ Furthermore, it addresses over 40% of global
carbon emissions, making it a crucial segment in carbon capture efforts.^133^ Amine solvent absorption is the most common
postcombustion CO2 capture method but is limited by high
costs and energy use.^134,135^ Membrane technologies are generally
viewed to be more energy-efficient and scalable. To selectively separate
CO2, a range of polymer-based membranes, such as polysulfone,
poly(vinyl alcohol), polyacrylamide, and polyvinylamine, have been
widely utilized. However, many of these membranes face a trade-off
between selectivity and permeability, leading to an ongoing search
for alternative materials that can provide more efficient membrane
performance.^136^ ILs have drawn considerable
interest for CO2 capture due to their distinct properties,
such as high thermal stability, low volatility, and the ability to
tailor their structure through different cation and anion choices,
resulting in excellent CO2 solubility and selectivity.
Pure ILs offer limited surface area and low CO2 capture
capacity, and their high viscosity, costly production, uncertain toxicity,
and potential environmental impacts further limit their industrial
applications.^137,138^ Consequently, recent research
has increasingly shifted toward incorporating ILs into membrane processes
to enhance their performance and overcome these limitations. These
include supported IL membranes (SILMs), IL composite polymer membranes
(ILPMs), IL composite mixed matrix membranes (ILMMMs), poly(IL) membranes
(PILMs), IL gel membranes (ILGMs), and IL membrane contactors (ILMCs).
Such approaches enhance CO2 capture efficiency by minimizing
the required amount of active phase for specific processes while also
facilitating the recovery and reusability of ILs.
SILMs represent
one of the most popular membrane-based approaches for CO2 capture and consist of a porous support material that traps an IL
within its pores, allowing for greater interaction with CO2. During operation, the membrane is compressed between two
one containing the CO2 feed phase and the other filled
with a receiving or stripping agent. A recent study by Mulk et al.
addressed the challenges of high energy requirements for solvent regeneration
and its toxicity in industrial CO2 capture by utilizing
the tributyl-tetradecyl-phosphonium chloride ([P44414^+^][Cl*^–^*]) IL,
as a solvent.^139^ This IL was chosen for
its long alkyl chain substituent, which enhances CO2 solubility
in postcombustion capture. Of the three hydrophobic supports tested,
the polytetrafluoroethylene-supported membrane performed the best,
showing high CO2 permeability and selectivity over N2 without IL leaching. Additionally, its durability suggests
it could be effective for long-term CO2 capture from large
volume flue (exhaust) gases, making it a promising alternative to
traditional amine-based solvents. Zhang et al. designed and prepared
SILMs containing ILs with a series of imidazolium cations paired with
phenolated anions that have dual-site interaction centers to isolate
CO2 from N2.^140^ 1,3-Dialkylimidazolium
cations paired with basic anions have shown great potential as absorbents
for CO2 because of their ability to react with CO2 to form carbene–CO2 adducts. However, the strong
interaction between carbene and CO2 makes it challenging
to release the absorbed CO2.^141,142^ By pairing imidazolium cations with phenolated anions, the CO2 could be more easily desorbed due to the transfer of CO2 from carbene to phenolated anion. Remarkably high CO2 permeability and excellent selectivity for CO2 over N2 was also achieved. Although SILMs have been employed
in various innovative applications for CO2 capture, they
do have some limitations. For instance, high pressure can lead to
the leakage of the IL from the membrane’s supporting pores,
which can compromise their long-term stability.
Ionic liquid
mixed matrix membranes (ILMMM) represent an innovative
approach to overcome limitations of SILMs. Mixed matrix membranes
(MMMs) are produced by incorporating porous fillers like zeolites,
graphene oxide, carbon nanotubes, metal oxides, and metal–organic
frameworks (MOFs) into a polymer matrix. By combining the high selectivity
of these fillers with the processability of polymers, MMMs offer enhanced
performance in gas separations.^143^ Habib
et al. reported a study where a specific IL, 1-methyl-1-propyl pyrrolidinium
dicyanamide ([C3MPyr*^+^][DCA^–^]), was introduced as a filler in MMMs
for the first time because of its high CO2 solubility.^143^ The membranes consisted of this IL with a MOF
(MIL-101(Cr)), known for its large surface area and strong interactions
with CO2, that were blended with varying amounts of a polymer
called Pebax. The prepared MMMs were very effective at separating
CO2 from nitrogen and methane. In a study by Chang et al.,
a MMM was created by first modifying covalent organic frameworks (COFs)
with an imidazolium-based IL, 1-ethyl-3-methylimidazolium ([C2MIm^+^]) [NTf2^–^*], and then incorporating this modified
COF into a polymer, known as PIM-1.^144^ This
modification increased the COF’s affinity for CO2, reduced its pore size, and improved its compatibility with PIM-1.
As a result, the developed membranes achieved significantly enhanced
CO2/N2 separation, exceeding previous performance
benchmarks.
Other membrane separation processes such as ILPMs,
PILMs and ILGMs
have also been used for CO2 capture. Klepić et al.
reported the preparation and testing of a stable ILPM made from PVA
and the [C2MIm*^+^][DCA^–^*] IL to effectively separate CO2 from H2, taking advantage of PVA’s polar nature.^145^ The membranes were prepared by mixing different
amounts of IL into PVA. As the amount of IL increased, the membranes
improved significantly in their ability to permeate CO2 and H2. Specifically, when the IL content exceeded 20
wt %, the membranes exhibited a phenomenon known as “reverse
selectivity”, where CO2 permeates faster than H2. Conversely, at lower concentrations of IL, the membranes
allowed H2 to permeate more easily. This versatility in
gas separation under different conditions opens new possibilities
for practical applications. Zhang et al. reported the design and synthesis
of novel PILs containing amino functional groups, which were then
used to create composite membranes by casting them on polysulfone
membranes.^146^ This approach resulted in
highly CO2 selective membranes with excellent CO2/N2 separation performance. Yu et al. presented a simple
and eco-friendly method to prepare double-network (DN) ion gel membranes
with excellent mechanical properties and CO2/N2 separation performance.^147^ Using a “one-pot”
method, the researchers combined two networks with an IL and prepared
the DN membrane with heat and UV light. The design boosted both the
strength and CO2 separation by adjusting the network density
and IL content, surpassing previous performance standards for CO2/N2 separations. Numerous studies have focused
on advancing CO2 capture and separation technologies. Within
this review, several unique IL-based approaches have been highlighted,
but for further in-depth information on the topic, reviews by Solangi
et al.^148^ and Yan et al.^138^ are highly recommended.
Environmental Pollutants
Membrane
separation processes extend well beyond CO2 capture and
offer solutions in diverse fields. In a recent study, Imdad et al.
developed a novel approach by transforming polyethylene terephthalate
(PET) bottles into polymeric membranes, which served as supports for
the Aliquat 336 IL in fabricating a SILM.^128^ These PET-derived SILMs were then applied to efficiently remove
hexavalent chromium (Cr (VI)), a hazardous pollutant, from contaminated
water. This method addresses both plastic waste management and water
pollution simultaneously. A study by Khalid et al. presented an innovative
approach where an imidazolium-based IL, functionalized with biocompatible
hydroxyapatite derived from fish scales, was incorporated into cellulose
acetate to create three distinct IL membranes.^127^ These membranes achieved efficient removal of toxic dyes
from wastewater, eliminating 98% of the cationic dye crystal violet
and 96% of the anionic dye congo red within 24 h, and also demonstrated
strong antibacterial activity. This research offers practical lab
protocols and industrial applications for sustainable environmental
pollution reduction. Merlet et al. developed a separation process
to selectively remove butanol from an acetone-butanol-ethanol solution
using a tubular membrane and an IL for in situ extraction.^149^ The objective was to ensure selectivity to
prevent the extraction of acetone, ethanol, and water, thus eliminating
the need for additional purification steps. The experiments demonstrated
the successful separation of butanol from aqueous solutions, providing
valuable insights for biofuel extraction by integrating membrane technologies
with green solvents. Furthermore, the system has the potential for
direct coupling to a fermenter to enhance efficiency.
Electrophoresis (CE) and Electrokinetic Chromatography (EKC)
CE is a commonly used separation technique for biomolecules that relies on the electrophoretic mobility of the analytes and the electroosmotic flow (EOF) induced by an applied voltage and the surface charge of the capillary.^150^ Electrophoretic mobility is dependent on the hydrodynamic radius of the analyte as well as its charge and is generally unique for each analyte. In CE, the EOF is the bulk flow of the background electrolyte (BGE) solution when a voltage is applied, and is dependent upon the charge of the inner capillary wall. When the capillary surface is negatively charged (as in the case of unmodified capillary) positive ions from the BGE form a double layer on the surface and the freely mobile, hydrated cations migrate toward the cathode when the voltage is applied, producing a bulk flow that carries analytes toward the detector. However, the direction of the EOF may be reversed by altering the capillary surface charge either through the use of permanent or dynamic capillary coatings.^151^ Suppressed or reversed EOF can have advantages of improved selectivity and sharper peaks depending on the analytes and experimental conditions.^152^ CE is known for its high separation efficiency, faster analysis times, and low sample volumes compared to HPLC, but has suffered from challenges due to internal temperature gradients and inconsistent surface charges.^153^ However, improvements to CE methodologies have been achieved using ILs and have mainly centered around separations involving EKC.
ILs in CE first gained attention when used as coatings to modify the capillary surface and control the EOF.^154,155^ Research in this area dwindled over the last five years with greater focus on ILs as pseudostationary phases for EKC. In EKC, the BGE contains an additive to which analytes partition to or interact with, resulting in a more complex separation mechanism involving the electrophoretic mobility of the free analyte, the mobility of the analyte-additive complex, and binding constants/partitioning coefficients of the analytes. Common applications of EKC include enantioseparations achieved by adding chiral selectors, such as CDs to the BGE.^156^ In this case, racemic mixtures can be separated based on the chirality of the enantiomer and its interactions with the CD chiral selector. EKC offers a significant advantage over traditional chromatographic methods as enantiomers with equal binding constants can still be separated based on the varying electrophoretic mobilities of the formed complex,^157^ which is especially important for pharmaceutical compounds that are chiral and whose enantiomers have different biological or pharmacological activity.^158^ Recently, a synergistic effect between CILs and CD has been observed^159^ and are thought to result from specific ion-pairing interactions. Often no enantioselectivity is achieved by using the CIL alone, but significant improvements in selectivity and peak shape can be achieved by a combination of CIL and CD compared to the CD alone.^32^
Zhang et al. explored the effect of CILs consisting of the tetramethylammonium
([N1111^+^]) cation and amino
acid anions, l-glutamate [l-Glu*^–^], l-arginine [l-Arg^–^], and l-proline [l-Pro^–^], on the enantioseparation of model drug compounds (i.e.,
amlodipine, citalopram, nefopam, tryptophan, and sulconazole) compared
to α-CD chiral selector under aqueous conditions.^160^ Incorporation of the CIL was observed to decrease
the EOF, affording more opportunities for analyte-CD interactions,
but was determined to not be the main cause of the synergistic effect
observed with CIL/α-CD systems. Additionally, higher resolution
was achieved for all five model drugs when the CIL was included in
the BGE compared to when [N1111–OH^+^] and [l-Arg^–^] were included, suggesting that this effect is not a result of the
individual CIL components alone. The inclusion complex formed between
the enantiomers and the α-CD was instead thought to be stabilized
by interactions of the [N1111^+^] cation with α-CD, thereby preventing interactions between
the enantiomers and the surface of the α-CD macrocycle. In the
work by Salido-Fortuna et al., the synergistic effect of additional
amino acid CILs, [N1111^+^][l-Lys^–^], [N1111^+^][l-Glu^–^], tetrabutylammonium ([N4444^+^]) [l-Lys^–^],
and [N4444^+^][l-Glu^–^], were explored along with ten different
CD chiral selectors to improve the enantioseparation of seven drugs
molecules (i.e., nadolol, metoprolol, terbutaline, duloxetine, verapamil,
econazole, and sulconazole).^161^ The best
chiral discrimination was realized with the 2-hydroxypropyl-β-CD
(HP-β-CD) under acidic conditions resulting in discrimination
of five of the seven racemic mixtures. When 5 mM of HP-β-CD
was combined with 30 mM of the CIL, a 2-fold improvement in enantioresolution
was achieved although better resolution was observed with the [N4444^+^] CILs than the [N1111^+^*] CILs for the studied drug mixture.
Migration times were also significantly increased with some even greater
than 60 min. Ultimately, separations featuring higher selectivity
allow for more efficient separations to be achieved since higher voltages
can be employed without risking loss of resolution, though faster
separations of ibrutinib enantiomers were separated in another study
by employing 2-sulfated-γ-CD (S-γ-CD) in negative polarity
mode.^162^
Nonaqueous CE conditions,
in which the BGE consists of an organic
solvent instead of water, can sometimes be employed to improve the
solubility of analytes, increase compatibility with MS detectors,
reduce analysis times, or alter the selectivity of the separation.^163^ In a study by Ren et al., tetraalkylammonium
amino acid CILs were employed with β-CD to separate dansyl-amino
acid enantiomers.^164^ In this work, N-methylformamide was used as the organic solvent in the
nonaqueous buffer solution to improve the solubility of β-CD
and allowed for higher β-CD concentrations to be used. By employing
a 100 mM β-CD concentration under nonaqueous conditions, six
dansyl-amino acids could be separated with resolution between 1.29
and 1.84 compared to a β-CD concentration of 10 mM in aqueous
conditions, in which the enantiomers could not be separated. For a
synergistic system with the [N1111^+^][l-Arg*^–^] IL, significant
improvements in resolution, peak shape, and separation efficiency
were also noted. Through molecular docking simulations, association
between [N1111^+^][l-Arg^–^] and β-CD was shown
to favor analyte binding, but the presence of the CIL appeared to
strengthen inclusion complexation of the dansyl-amino acids. Slight
enantioseparation of dansyl-amino acid enantiomers was also achieved
for the first time using the [N1111^+^][l-Arg^–^] IL
as the sole chiral selector, suggesting that CILs can participate
in enantiorecognition. Zhang et al. expanded the list of possible
CILs to include tartaric acid with various cation combinations and
demonstrated that the cation can affect enantiorecognition of ten
amino alcohols.^165^ The CIL was used in
this case as the chiral selector in the aqueous–organic BGE
consisting of 80–90% methanol. When [N1111^+^], [N2222^+^], and [N4444^+^] cations were
used with a tartaric acid anion, resolution of amino alcohol enantiomers
was improved compared to the tartaric acid chiral selector alone and
dicationic CILs afforded even greater enantioseparations.^166^ Compared to other cations (including imidazolium,
pyridinium, phosphonium, pyrrolidinium, piperidinium, and cholinium),
significant differences in selectivity, peak shape, and migration
times were observed, attributed to better separations of larger cations
with enantioresolution decreasing in the order of [C4MPyr^+^]2[l-TT^–^], [C4MPip^+^]2[l-TT^–^], and [C4MIm^+^]2[l-TT^–^*].^165^ The
mechanism influencing enantioselectivity was thought to be due to
a steric hindrance effect, but additional studies are needed to confirm
this and assess other possible contributing factors.
To further
enhance enantioseparations, micellar electrokinetic
chromatography (MEKC) has been employed and has a similar separation
mechanism to EKC, but also relies on the partitioning of the analyte-chiral
selector complex to the micellar phase. In MEKC, surfactants are present
in the BGE above the critical micelle concentration and form micelles
in the buffer solution that act as a pseudostationary phase. Feng
et al. used the 1-butyl-3-methylimidazolium dodecyl sulfate ([C4MIm*^+^][C12SO4^–^*]) IL with a clindamycin phosphate
chiral selector to separate six racemic drug molecules.^167^ Compared to the MEKC separation using SDS,
the enantioselectivity of the IL-based method was increased and resulted
in significantly better peak shapes.
Monolithic columns containing
ILs have shown promise in EKC methods.^168^ In general, monolithic columns consist of a highly porous, interconnected
polymer and have become of interest in chromatographic separations
due to their high permeability, greater accessible surface area, and
rapid analyte mass transfer.^169^ Research
studies have explored modifications to the macropore structure of
monolithic columns that control these properties.^170^ Huang et al. developed a novel polyhedral oligomeric siloxane-based
zwitterionic monolithic capillary columns featuring retention-independent
plate heights and found that the [C6MIm^+^][BF4^–^] IL porogen played an important role in
controlling the mesopore structure^171^ responsible
for analyte retention and column selectivity.^172,173^ While the mesoporous structure (2–50 nm) can be detrimental
to small-molecule separations in HPLC due to poor stationary phase
mass transfer, this is not the case in electrokinetic separations
due to the presence of an EOF facilitating highly efficient separations.^170^ Huang et al. applied this column for hydrophilic
interaction capillary electrokinetic chromatography (HI-EKC) and explored
the separation mechanism using benzoic acids, nucleosides, nucleobases,
and glycopeptide antibiotics.^171^ Mixed-mode
retention mechanisms were confirmed in both HILIC and RP mode due
to additional ion-exchange and electrostatic interactions. A strong
anodic EOF was also achieved, especially under lower pH conditions,
allowing for faster separations of negatively charged analytes with
narrower peaks and suitable run-to-run and column-to-column repeatability
under HI-EKC conditions.
Monolithic porous layer open tubular (PLOT) columns for EKC have also become of interest as higher EOF and lower back pressure are achieved and allow for higher loading capacities and high separation efficiencies. In a study by Zhou et al., the 1-allyl-methylimidazolium chloride IL ([AMIm*^+^][Cl^–^*]) monomer was copolymerized with styrene and ethylene dimethacrylate cross-linker to form a monolithic PLOT column for EKC-MS.^174^ A strong anodic EOF was achieved between pH 2–8 and could be modulated by controlling the amount of IL in the polymer. By modifying the EOF through the IL concentration, separation of amino acids was accomplished in which the enhanced EOF superseded the electromigration rate of the amino acids. When applied for the analysis of neutral analytes, separation of various model analytes was achieved through hydrophobic and π–π interactions, and when applied for the separation of parabens, baseline resolution of methyl, ethyl, and propyl paraben was achieved within 12 min that could not be achieved using CE alone.
While CE and CE-related
methods are the most employed electromigration techniques, the term
at its core refers to the movement of an ion or charged particle under
the influence of an electric field. Due to their conductive properties,
ILs have been employed in various techniques in which electric fields
are applied, including ABS, membranes, and microfluidic devices.^175−177^ In the case of ABS, the applied voltage aided to induce phase separation
between the kosmotropic salt phase and the IL-containing phase,^175^ allowing for more rapid extractions. In free-flowing
IL membranes, the permeability and selectivity for CO2 capture
were improved and controlled by applying an electric field, resulting
in denser packing of the migrating IL molecules near one side of the
membrane.
Microfluidic devices are designed
for handling small liquid sample volumes using micrometer sized channels
and chambers, often for the analysis of cells and biomolecules.^178^ Microfluidic devices can be integrated with
electrodes for the capture of charged particles/molecules within the
chambers for subsequent analysis.^179^ One
such application designed a device featuring microchip capillary electrophoresis
for the separation and online detection of flavins.^177^ In this method, the 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide
([C4MIm^+^][NTf2^–^]) IL was used as a hydrophobic, low viscosity liquid to compartmentalize
the sample and minimize changes in sample volume. Compartmentalization
occurred electrokinetically, and the IL plugs were determined to be
optimal at 1–10x the capillary diameter for repeatable sample
introduction. Once the IL migrated into the microchip, surface adsorption
prevented the IL from traveling further, resulting in the sample breaking
through the IL plug due to the maintained EOF. Results showed a 6.3-fold
improvement in peak intensity compared to conventional electrokinetic
injections. However, higher relative standard deviation values were
obtained for this method and may be due to residual IL effects on
the EOF.
ILs have also been used in microfluidic devices to
seal chambers after capturing analyte(s) of interest.^180^ Banovetz et al. utilized dielectrophoresis
to capture tumor cells (MDA-MB-231) into microfluidic chambers for
single cell analysis through the use of the 1-decyl-3-methylimidazolium
([C10MIm^+^]) [NTf2^–^] IL.^181^ Due to the conductive nature
of the IL, cell lysis was possible for a subsequent enzymatic assay
to assess β-galactosidase activity, a prominent biomarker used
for early detection of breast cancer. The method was able to demonstrate
a high degree of heterogeneity in the expression of β-galactosidase
among 258 individual cancer cells, suggesting that different subpopulations
of tumor cells may require different types of treatments.
Field-Flow Fractionation (EI-FFF**)**
Liu et al.
using an IL/mesoporous silica coated electrodes for the
separation of microparticles by EI-FFF.^182^ In traditional FFF, a liquid solution is passed through a narrow
channel, and separation occurs based on the particles’ mobilities
under an applied field (electric, magnetic, gravitational, thermal,
hydraulic, or centrifugal).^183^ These fields
are often applied perpendicular to the laminar flow of the sample
to cause the particles to accumulate near the wall of the channel,
resulting in a concentration gradient based on translational diffusion
coefficients. Since the flow velocity near the wall is slower than
near the center of the channel, separation based on analyte diffusion
can be achieved as smaller, more diffuse particles are more likely
to migrate away from the wall into the higher velocity flow region.
In EI-FFF, an applied voltage results in the migration of the charges
particles to the accumulation wall and separation depends on the diffusivity
of the particle as well as its electrophoretic mobility. Recently,
cyclical EI-FFF (CyEI-FFF) was developed and utilizes stepwise switching
of the electric field’s polarization to produce higher separation
efficiencies.^184^ Liu et al. employed a
stainless steel channel coated with the IL/mesoporous silica material
acting as an electrode and containing a second platinum electrode
coated with the same material.^182^ The methyltri-N-octylammonium
bis(trifluoromethanesulfonyl)imide ([N1118^+^][NTf2^–^]) IL was chosen for its wide electrochemical
window and resulted in the formation of annular channels in which
higher laminar flow velocities existed in the center of the two electrodes.
The particles oscillated within the annular channel between the two
electrodes as the alternating current was applied and separation occurred
based on the particles size, charge, and morphology due to influences
of electrophoretic force, electrostatic force, and viscous force.
Two operation modes were examined and were applied for the separation
of polystyrene particles of various sizes. The separation mechanism
for this method is shown in Figure 5 with separation based on particle size being achieved
with resolution values greater than 1.22.

Among the various physical properties of ILs discussed so far, their high conductivity, excellent electrochemical stability, and wide electrochemical window make them well-suited for numerous electrochemical applications.^185−187^ As such, ILs have been utilized in the development of ion-selective sensors, reference electrodes, voltametric sensors, gas sensors, and biosensors.^188−190^ This section focuses on the application of ILs in electrochemical sensors with an emphasis on their incorporation into reference electrodes and ion-selective electrodes.
A reference electrode provides a stable and known reference potential that enables measuring potential changes of the working electrode.^191^ The Ag/AgCl electrode is one of the most widely used reference electrodes in electrochemistry due to its stability and simplicity. The reference electrode contacts the sample solution through a salt bridge filled with an internal electrolyte solution consisting of nearly equal transference numbers for cations and anions. Typically, concentrated KCl is used to minimize the liquid junction potential at the interface with the sample and provides a stable, sample-independent reference potential. However, this type of electrode and required set up has certain drawbacks, such as variations in KCl concentration, the need for regular maintenance, dependence of the liquid junction potential on the junction material type, and challenges with miniaturization.^192^ An approach to address these limitations is the development of an IL-doped reference electrode membrane, which eliminates the need for a conventional aqueous salt bridge.^193^ The interface between the IL and the aqueous sample solution creates a consistent interfacial potential that remains unaffected by the concentration and ionic strength of the aqueous phase. Herein, we describe a few recent applications employing ILs in the manufacturing of reference electrodes.
Kuczak et al. examined basic physicochemical properties of various
ILs on the performance of polymeric membrane reference electrodes.^194^ Seven ILs containing cations featuring different
hydrophobicity, including trihexyltetradecylphosphonium, 1-hexyl-1-methylpiperidinium,
1-pentyl-1-methylpiperidinium, 1-benzyl-3-methylimidazolium ([BzMIm]),
1-(2-methoxyethyl)-3-methylimidazolium, 1-(2-hydroxyethyl)-3-methylimidazolium
([C2OHMIm]), and triethylsulfonium cations with [NTf2^–^] anions were incorporated into polyurethane/o-nitrophenyl
octyl ether (PU/o-NPOE) (1:2) membranes. The stability of the measured
potential for the membrane-based reference electrodes was then tested
under different conditions and indicated that hydrophobicity differences
between IL cations and anions contributed to a strong potentiometric
response for lipophilic ions. The study also evaluated the potential
stability of IL-based polymeric membrane reference electrodes in aqueous
solutions containing different concentrations of KCl and NaCl as well
as their long-term stability in a solution with 125 mM NaCl and 5
mM KCl. Although all the IL-based electrodes provided better stability
in comparison with a blank membrane, electrodes containing membranes
of [BzMIm*^+^][NTf2^–^] and [C2OHMIm^+^*][NTf2^–^] provided the best stability. By testing membranes
containing 1%, 2%, and 3% IL, the study showed that varying IL concentrations
within the polymer matrix did not significantly affect the electrode
capacity for maintaining stable potential in different solutions.
Since leaching of plasticizer from polymeric membrane electrodes can
be problematic membranes containing only PU and IL were tested and
it was found that the membranes without plasticizer can be applicable
in the development of reference electrodes.
Chen and co-workers
employed a biocompatible reference electrode
membrane doped with an IL.^195^ Among the
seven silicone materials tested, poly(3,3,3-trifluoropropylmethylsiloxane)
(referred to as fluorosilicone 1) doped with the [C8MIm*^+^][NTf2^–^] IL was
the only membrane matrix that performed effectively as a reference
electrode and provided a stable potential, as shown in Figure 6a. The use of silicone as a
membrane matrix not only eliminated the need for plasticizers but
is also biocompatible. To investigate the effects of IL chemical structure
and hydrophobicity on the stability and potential drift of the reference
electrode, fluorosilicone 1-based membranes doped with four different
ILs containing cations of varying hydrophobicity and paired with the
[NTf2^–^] anion were tested.
The results showed that membranes doped with [C8MIm^+^][NTf2^–^], [C10MIm^+^][NTf2^–^], and [C12MIm^+^][NTf2^–^] ILs exhibited minimal potential changes across
concentrations of KCl, as shown in Figure 6b. Finally, long-term stability tests indicated
that fluorosilicone 1 reference electrodes doped with the [C8MIm^+^*][NTf2^–^] IL exhibited minimal potential drift, measuring 20 μV h^–1^ in artificial blood and 112 μV h^–1^ in serum over 8 and 5.8 days, respectively. Figure 6c represents the potential stability over
time of the optimized electrode.^195^
![Figure 6: (a) Represents
the effect 1.0–16 mM KCl on the potential
of reference electrodes incorporating [C8MIM*^+^][NTf2^–^]-doped silicone membranes compared to a free-flow double junction
reference electrode. (b) Effect of 1.0–16 mM KCl on the potential
of Fluorosilicone 1 reference electrodes doped with various ILs including
[C8MIM^+^][NTf2^–^], [C10MIM^+^][NTf2^–^],
[C12MIM^+^][NTf2^–^], and [N1444^+^][NTf2^–^] ILs. (c) Shows long-term EMF measurement results conducted using
a solid-contact reference electrode prepared with the [C8MIM^+^][NTf2^–^*] IL immersed in artificial blood electrolyte solutions.
Reproduced from Chen, X.V.; Stein, A.; Bühlmann, P. Reference
Electrodes Based on Ionic Liquid-Doped Reference Membranes with Biocompatible
Silicone Matrixes. ACS Sens. 2020, 5, 1717–1725 (ref (195)). Copyright 2020 American
Chemical Society.](ac5c00264_0006.jpg)
The development of reference electrodes incorporating silicone membranes doped with ILs has extended beyond the aforementioned study due to the promising results in miniaturization and biocompatibility of these electrodes. Dong et al. introduced an innovative fabrication method that uses PDMS membranes doped with ILs, combined with colloid-imprinted mesoporous carbon (CIM) as a solid contact layer.^196^ The study identified that the catalyzed polymerization of the silicone causes the hydroxyl-terminated polydimethylsiloxane oligomers to cross-link, forming large structures that cannot penetrate the pores of the CIM carbon. Consequently, after the solvent evaporates, the pores of the CIM carbon are filled exclusively with the IL. The depletion of ILs in the reference membrane increases the membrane’s resistance and compromises overall electrode function. To address this, two strategies were investigated including presaturation of mesoporous carbon with IL before adding the silicone-based solution and increasing the IL concentration to counter the sequestration effect. These approaches allowed for the creation of stable reference electrodes with enhanced long-term performance and potential stability, especially for applications in biocompatible and miniaturized sensors.
with Ion Selective Electrodes
ILs have also been investigated in potentiometry applications with ion-selective electrode (ISEs). ISEs enable detection of ionic chemical species with good selectivity and low detection limits. Solid-state ISEs are often designed with an intermediate layer to facilitate the connection between electronic conductors and the ion-selective membrane. Due to their ionic nature and ability to polymerize ILs have proven to be interesting materials for preparing ISE membranes with enhanced stability and ion transport. The most recent applications of ILs in solid-state ISEs are presented in this section
Wardak et al.
reported a lead-sensing method using solid-state ISEs in which the
polymeric membrane was modified with a nanocomposite of carbon nanofibers
and an IL.^197^ While the use of the [C6MIm*^+^*][PF6^–^] IL as a solvent for lead preconcentration and as a lipophilic component
in lead-selective membranes has been previously demonstrated,^198^ this study leveraged π-electrons in the
imidazolium ring to interact with the π-surface of carbon nanofibers.
This interaction was found to facilitate the formation of an electrochemical
stabilization and steric nanocomposite, which was then used to modify
the polymer membrane in a solid-contact lead ion-selective electrode.
For membrane preparation, the nanocomposite was combined with low-molecular-weight
poly(vinyl chloride) (PVC), bis(1-butylpentyl) adipate (BBPA), 2-nitrophenyl
octyl ether (NPOE), and a lead ionophore, with the proportion of nanocomposite
tested ranging from 0–9% by weight. The modification enhanced
sensitivity, broadened the measurement range, increased the membrane’s
hydrophobicity, and improved selectivity coefficients. Additionally,
the modified membrane reduced leaching of active ingredients, thereby
enhancing the electrode’s long-term stability.
In another
study, Wardak et al. employed a nanocomposite of multiwalled
carbon nanotube (MWCNTs) and the [C4MIm*^+^][PF6^–^] IL for copper ISEs.^199^ MWCNTs were found to facilitate charge transfer
between the internal electrode and the membrane, while the IL reduced
resistance and improved ion transport. The copper ISE demonstrated
enhanced selectivity, lower detection limits, and a broader measurement
range compared to its unmodified counterpart. Similarly, Pietrzak
et al. developed a solid-state nitrate ISE using a nanocomposite of
MWCNTs and the trihexyltetradecylphosphonium chloride ([P66614^+^*][Cl^–^]) IL to examine
the effects of MWCNT dimensions (length and diameter) on electrode
performance.^200^ The nanocomposite-based
electrodes showed a broader linear range and better calibration slope
compared to nonmodified electrodes and the results indicated that
the porosity, surface area, and homogeneity of MWCNTs influenced the
electrode’s response, with higher porosity and structural homogeneity
positively impacting electrode performance.
Inorganic materials
can also be used for modifying SC-ISEs, based
on redox capacitance or double-layer capacitance transduction mechanisms.
Zeng et al. proposed using Ag@AgCl/1-tetradecyl-3-methylimidazolium
chloride (Ag@AgCl/[C14MIm*^+^][Cl^–^]) as an inorganic redox buffer in solid-contact
Ca^2+^-selective electrodes via a redox capacitance mechanism.^201^ The [C14MIm^+^][Cl^–^] IL provided a stable source of chloride
ions and enhanced the conductivity properties of the buffer. The electrode’s
performance was evaluated in terms of stability, response time, impedance,
and resistance to interference from light, oxygen, and carbon dioxide.
The Ag@AgCl/[C14MIm^+^][Cl^–^*] buffer exhibited high redox capacitance,
offering stable potentials and rapid response times. Finally, the
electrode’s performance was successfully demonstrated in measuring
calcium ions in seawater samples.
In MS, ILs are generally utilized to increase signal intensity. The most common way ILs are used to achieve signal enhancement are as matrices for matrix-assisted laser desorption ionization (MALDI)-MS and as complexing agents for electrospray ionization (ESI)-MS. This section discusses recent literature on ILs for MS covering new applications, sample types, and interface designs.
Electrospray Ionization
In ESI, ILs can be introduced during the ionization process to act as a complexing agent; this is specifically done with DILs. When an anionic analyte undergoes complexation with a DIL, the resulting species carries a positive charge, allowing the analysis to be carried out in positive ion mode (i.e., measuring positive analytes).^31^ This process is called polarity switching or a charge inversion reaction and provides signal enhancement due to the minimized effect of the corona discharge in positive versus negative ion mode.
A common application of polarity switching is for the measurement
of per and polyfluorinated compounds (PFCs). Li et al. described the
use of the 1,1-bis(3-methylimidazolium-1-ly)butylene difluoride ([(MIm)2C4^2^^+^] 2[F*^–^]) IL complexed with PFCs for ionization
and signal enhancement.^202^ They measured
a mixture of ten PFCs first using supramolecular solvent based extraction
and ultrahigh-performance supercritical fluid chromatography. A makeup
liquid comprised of [(MIm)2C4^2^^+^] 2[F^-^] and acetonitrile was
then mixed with the effluent post column. The mixture was ionized
via ESI prior to MS analysis using a triple quadrupole mass analyzer.
Results showed that using the DIL complexing agent in positive mode
provided more sensitive detection of PFCs with one to 2 orders of
magnitude signal enhancement compared to performing measurements in
negative ion mode with no complexing agent. Li et al. used DIL-based
charge inversion and a miniaturized MS to measure PFCs in biological
matrices.^203^ This work also used an in
capillary dispersive magnetic SPME method based on aptamer-functionalized
polymer-modified magnetic nanoparticles that allowed for analyte enrichment
prior to MS analysis. The same capillary system used for extraction
also functioned as a nano ESI emitter. In this system, DILs were introduced
inside of the capillary extraction system in a plug near the capillary
tip. Ten different DILs with varying side groups and linkage chains
were tested to investigate their binding affinity for PFCs; the dicationic
IL structure was found to be crucial for the charge inversion reaction.
Their results showed that the [(MIm)2C4^2+^] 2[F^–^*]
IL gave the highest signal intensity with 6.3–28.9 times the
signal intensity in positive ion mode using DIL-based charge inversion.
Furthermore, the method examined detection of PFCs in human blood.
DIL based charge inversion has also been used for the measurement
of haloacetic acids with ESI-MS.^204^
Charge inversion reactions based on DILs can also be used with
ionization techniques outside of ESI. Guo et al. used the technique
for matrix-assisted ionization in the analysis of PFCs within environmental
water samples.^205^ In this technique, the
sample followed by the DIL matrix ([(MIm)2C4^2+^] 2[F*^–^*] and acetonitrile) were spotted onto paper and placed near the MS
inlet. The intrinsic vacuum from the inlet led to sublimation of the
matrix and analyte while at the same time forming positively charged
complexes. From sampling to results, the approach took only 1 min
and provided signal enhancements up to 2 orders of magnitude in positive
ion mode. PFCs were also measured using a DIL for ionization enhancement
with easy ambient sonic-spray ionization MS.^206^
Xi and Muddiman utilized DIL charge inversion reactions post
MALDI
to expand metabolomic coverage for mass spectrometry imaging (MSI).^207^ In this work, the 1,5-pentanediyl-bis(1-butylpyrrolidinium)
difluoride ([(BPyr)2C5^2^^+^] 2[F*^–^*]) IL was
introduced after MALDI using an ESI interface. This technique permitted
measurement of 73 negative analytes complexed with the DIL along with
164 positively charged analytes, providing a 44% increase in molecular
coverage. Figure 7 shows
mass spectra from this study comparing the results of positive ion
mode with and without the use of DIL for charge inversion, highlighting
the increased molecular coverage. This study also demonstrated the
applicability of their technique for MSI of a hen ovary, showing a
rapid and effective way to detect positive and negative analytes of
interest in one measurement.
![Figure 7: Mass spectra showing positive ion mode with
[(BPyr)2C5^2^^+^] 2[F*^–^*] complexation (purple,
top) and positive
ion mode (orange, bottom). (A) Not reproduced. (B,C) Zoomed in sections
from (A). Labeled m/z values correspond
to DIL complexes with analytes from rat liver sections. Reproduced
from Xi, Y.; Muddiman, DC. Enhancing Metabolomic Coverage in Positive
Ionization Mode Using Dicationic Reagents by Infrared Matrix-Assisted
Laser Desorption Electrospray Ionization. Metabolites 2021, 11, 810
(ref (207)). Copyright
2021 by authors licensed to MDPI.](ac5c00264_0007.jpg)
Hu at al. demonstrated the use of an IL-based organic polymer for online coupling of in-tube SPME with MS using the 1-allyl-methylimidazolium chloride ([AlMIm**^+^][Cl^–^**]) IL.^24^ A custom MS/extraction interface using a fused silica capillary for the in-tube SPME and as the ESI emitter tip was created followed by mounting of the coated capillary onto a translational stage. When moved away from the MS inlet, the high voltage connection was broken, and the sample was loaded into the capillary for extraction. The interface was then moved toward the MS inlet to enable the connection of the high potential for ESI. Elution solvents were introduced, and analytes were then sprayed out from the capillary tip for ionization. The IL polymer provided a highly porous structure that not only provided high extraction efficiency but also enhanced the ionization efficiency of the ESI process. The polymer’s monolithic structure created microchannels at the tip of the ESI capillary, which provides multiple spray orifices for ESI creating smaller liquid droplets that were easier to evaporate and convert to gas phase ions. This study found that ionization efficiency was enhanced at optimized flow rates for the SPME capillary compared to more traditional ESI capillary geometries. Validation studies were conducted on nonsteroidal anti-inflammatory drug compounds producing high linearity from 0.1 to 200 ng mL^–1^ of ketoprofen and flurbiprofen, LODs from 0.02 to 0.03 ng mL^–1^, and limits of quantitation (LOQs) from 0.08 to 0.10 ng mL^–1^. The adaptability of this technique shows promise for applications toward numerous analytes by simply changing the IL polymer.
Liquid Matrices for Matrix-Assisted Laser Desorption/Ionization
MALDI-MS is an MSI technique that uses a UV laser to desorb small amounts of sample and matrix. MALDI-MS allows for the detection of intact large molecules making it ideal for metabolomics, proteomics, and lipidomics. The ionization mechanism in MALDI is complicated and not widely understood.^208^ Primary ionization occurs via proton transfer from an acidic matrix to the analyte molecules, and secondary ions form due to thermal ionization and continuing reactions in the desorption plume. The uncertainty and complexity in the MALDI process can lead to an unrepresentative sample to be measured. In combination with low mass range ions derived from the matrix and inconsistent shot-to-shot reproducibility due to heterogeneity in the film, MALDI-MS cannot be used for quantitative measurements. Ionic liquid matrices (ILMs) are promising alternatives to overcome both obstacles when used for MALDI-MS. The studies discussed in this section focus on using ILMs to better understand the ionization process, to overcome heterogeneity in the matrix coating, and enable the detection of low m/z molecules.
Kobylis et al. performed an extensive study examining the effect of ionic character/iconicity of protic ILs on the ionization process of MALDI.^209^ The iconicity of each protic IL was characterized using Walden plots, density functional theory studies, nuclear magnetic resonance spectroscopy, and thermal gravimetric analysis coupled to infrared spectroscopy prior to MALDI-MS analysis in negative and positive ion modes. The study found that the ionization process of MALDI is independent of the ionicity of the ILM and further studies are required to understand the ionization mechanism of ILMs in MALDI-MS.
Lin et al. explored the use of ILMs for the quantitative analysis of adenosine nucleotide ratios, which can provide valuable information on energy transfer in metabolism.^210^ In this study, the fragmentation yield, UV absorption, shot-to-shot reproducibility, signal intensity, and adenosine nucleotide ratios were examined with a traditional MALDI matrix and four ILMs. The 2,5-dihydroxybenzoic acid pyridine (DHBP) ILM was found to be the most effective due to lower UV absorption of the 355 nm laser and provided a milder ionization process which reduced fragmentation of the phosphate group, thereby providing higher signal intensities of the analyte ions. Additionally, the DHBP ILM also provided better shot-to-shot reproducibility which allowed for quantitative analysis of the adenosine nucleotides.
Mernie et al. explored the use of ILs for the measurement of oligosaccharides.^211^ To overcome significant challenges of MALDI-MS in measuring complex mixtures of carbohydrates related to their low ionization efficiency and inability of the mass analyzer to separate oligosaccharides with high structural similarity, ILs were used to stabilize the DHB metallic-nanoparticle (MNP) conjugated matrix that was coated on thin layer chromatography plates. The addition of ILs led to a more homogeneous DHB-MNP coating, resulting in more efficient ionization and fragmentation capabilities with up to a 28-fold increase in the intensity of precursor and fragment ions. The analysis scheme was applied to human milk oligosaccharide profiling and 25 oligosaccharides were detected using this one-step approach.
ILMs have also been utilized to measure high molecular weight molecules. A study by Yamazaki et al. used 3-aminoquinoline-based ILMs to measure cyclodextrin-based polyrotaxane (CD-PR) molecules up to 700 kDa using a MALDI time-of-flight MS with a high mass detector.^212^ The ILM differentiated double-stranded and aggregated forms of the CD-PR. Additionally, the ILM preferentially created singly charged ions that are desired at higher mass ranges.
and Optical Sensors
Recent studies have highlighted the remarkable potential of ILs in optical sensing applications. The design and development of sensors necessitates the careful consideration of factors such as selectivity, sensitivity, response time, the ability to differentiate between various analytes, and consistency in response.^213^ In addition to meeting the aforementioned sensor characterization requirements, IL-based sensors offer unique advantages including vast structural tunability and synthetic versatility, enabling the design of probes with specific anions and cations tailored to sensing needs.^214−216^ Furthermore, the high vapor pressure of ILs minimizes the effects of concentration changes due to evaporation, thereby enhancing detection stability. As a result, IL-based sensors have attracted significant attention, leading to numerous research efforts in this area. In this section, we will focus on the design of fluorescence and colorimetric sensors as well as their application in surface-enhanced Raman spectroscopy (SERS) in recent years.
Detection
Fluorescence detection is considered one of the most sensitive and selective optical sensing methods. ILs have contributed to the design of such sensors through various mechanisms, including the incorporation of fluorophores into the IL chemical structure, facilitating interactions between ILs and analytes, modifying the fluorescence properties of ILs upon analyte interaction, and enabling charge transfer processes.^217^ These interactions have driven the development of several IL-based sensors capable of detecting a wide range of targets, including gases, ions, organic compounds, inorganic compounds, and biological molecules.
FILs have attracted
significant attention for their unique optical properties, with various
types being synthesized for applications in chemical sensing. For
example, benzobis(imidazolium) ILs, salicylate-bearing FILs, quinolizinium-based
FILs, metal-ion-coordinated FILs, and polyamidoamine dendrimer-derived
FILs are among some of the FILs introduced in recent years.^218^ Building on this progress, Gan et al. designed
and developed the [P66614^+^][HQS*^–^] FIL for the sensitive and selective
detection of Al^3+^.^218^ This innovative
probe integrated 8-hydroxyquinoline-5-sulfonic acid [HQS^–^] as the anion, thereby leveraging its fluorophore
and binding moiety properties. Compared to the traditional HQS probe,
the [P66614^+^][HQS^–^] FIL exhibited enhanced sensitivity, selectivity,
and binding strength and achieved a LOD of 5.5 × 10^–8^ M, which is significantly lower than HQS (2.4 × 10^–7^ M), and a binding constant of 7 × 10^4^, also much
higher than HQS (6 × 10^3^). These improvements were
attributed to modified charge distribution in the FIL, which creates
a stronger interaction with Al^3+^ and stabilizes the probe-metal
complex. The detection mechanism relied on enhancing the fluorescence
characteristics, wherein the fluorescence intensity of the probe increaed
upon interaction with the analyte, enabling quantitative measurement.
Additionally, the [P66614^+^][HQS^–^*] FIL demonstrated faster response times
and superior fluorescence enhancement at low Al^3+^ concentrations,
making it highly effective for practical applications in aqueous environments.
FIL probes have also demonstrated exceptional potential in dual-channel
sensing, incorporating both colorimetric and fluorescence detection,
leading to significant advancements in the rapid and on-site determination
of environmental pollutants. Che et al. introduced the FIL probe containing
the [P66614^+^] cation with a
fluorescein-based anion [Fluo*^–^*]
for the sensitive and selective detection of paraquat, a widely used
herbicide with significant toxicity.^219^ The anion-functionalized probe enhanced analyte enrichment through
strong electrostatic attractions to cationic the paraquat, improving
both sensitivity and selectivity by excluding uncharged pesticides.
Additionally, this design reduced the distance between the probe and
analyte by extracting the analytes from the bulk, enabling faster
response times. In fluorescence detection, the probe-paraquat interaction
resulted in fluorescence quenching, yielding a LOQ of 64.0 nM. In
colorimetric detection, the solution’s color transitioned from
green to orange and finally to pink with increasing paraquat concentration,
achieving an LOQ of 100 nM. This dual-channel capability enabled real-time
visual monitoring of paraquat.
Another example highlighting
the development of real-time visual
monitoring using FIL probes was reported by Che et al. focusing on
monitoring trace amounts of mercury(II) in environmental and biological
samples.^220^ A different FIL probe was constructed
using a physical mixture of [P66614^+^] [RDB*^–^] (rhodamine B)
and 7-hydroxycoumarin, while incorporation of rhodamine B into the
IL chemical structure enhanced the electronegativity of the oxygen
atom on its phenoloxy group, thereby increasing its affinity for mercury(II)
and subsequently improving the selectivity of the probe. The addition
of 7-hydroxycoumarin expanded the colorimetric range of the probe
in the presence of Hg^2+^. While the [P66614^+^][RDB^–^] IL
probe alone exhibited a slight color change from yellow to orange,
the combination of [P66614^+^][RDB^–^*] and 7-hydroxycoumarin
provided for a distinct color transition from light white to opera
pink upon interaction with mercury(II), significantly enhancing the
performance of the colorimetric channel. Furthermore, the probe’s
potential for practical applications was demonstrated through its
integration into a paper-based sensor, enabling on-site visual monitoring
of Hg^2+^.
Biocompatible FIL probes have further expanded
their applications.
A curcumin (Cur)-based FIL probe, [N3333^+^][Cur*^–^], exhibited good
sensitivity for benzoyl peroxide (BPO) detection.^221^ The probe was constructed using the [N3333^+^][Cur^–^*] IL
and upon adding BPO, a distinct color change from blood red to nearly
colorless was observed and attributed to a redox reaction, enabling
its use in colorimetric detection. Furthermore, the presence of BPO
induced fluorescence quenching from bright yellow to colorless when
illuminated with 365 nm UV light. Fluorescence-based detection with
a reported LOD as low as 10 nM was achieved.
Dots and Photonic Spheres
Carbon dots are a relatively new
class of fluorescent dyes with diameters
of less than 10 nm.^222,223^ They have garnered significant
attention due to their advantages, including tunable photoluminescence,
biocompatibility, and resistance to photobleaching compared to organic
dyes and metallic quantum dots. However, their full potential has
been hindered by their tendency to aggregate and relatively low quantum
yields.^224^ ILs have been shown to offer
promising solutions to these limitations when used in the modification
of carbon dots by improving their detection limits and quantum yields.
Wang et al. reported an IL-CD probe for the determination of vitamin
B6 in milk.^225^ The probe was prepared using
a solvothermal method by mixing the [C8MIm*^+^][BF4^–^*] IL and o-phenylenediamine, followed by heating the mixture at a
specific temperature for a defined period of time. In the presence
of vitamin B6, a static quenching mechanism led to a significant reduction
in fluorescence intensity, enabling sensitive detection with a LOD
of 5 × 10^–5^ mg mL^–1^. Additionally,
the probe demonstrated good selectivity for vitamin B6 over other
vitamins and ions commonly found in milk, due to the specific analyte-probe
complexation that occurred.
Liu et al. introduced PIL-based photonic spheres as sensing elements for the colorimetric determination of five explosive compounds, including 4-nitrophenol, picric acid, 2,4,6-trinitroresorcinol, 2,4-dinitrophenol, and 1,3,5-trinitrotoluene.^226^ For PIL synthesis, an imidazolium derivative functionalized with a urea group as the monomer and hexamethylene diisocyanate as the cross-linker was used. The incorporation of urea-functionalized PILs resulted in strong hydrogen bonding between the urea motifs and the nitro groups of the analytes, offering high affinity to the PIL spheres. The direct binding mechanism enabled straightforward detection of the explosives, thereby avoiding complicated analysis procedures. Additionally, the ILs exhibited diverse intermolecular interactions allowing for single photonic sphere to exhibit versatile responses to a broad range of analytes.
Spectroscopy (SERS)
ILs and
deep eutectic solvents (DESs) have demonstrated promising results
in SERS by serving as agents to enhance the production and performance
of nanostructured substrates. The following section explains some
of the roles of ILs in SERS. Using the ability of ILs to stabilize
nanoparticles, Li et al. synthesized a SERS substrate based on the
1-methyl-3-hexyl imidazole ferric tetrachloride [C6MIm^+^][FeCl4^–^]) MIL gold nanoparticles
(Au NPs) using a microwave-assisted method.^227^ These substrates were successfully employed for the sensitive detection
of clopidol residues in egg samples. The study reported that the MIL
played a role in providing uniform particle distribution and sizes
that resulted in an amplified SERS signal and further guided the synthesis
of Au NPs with high performance.
Carreón et al. demonstrated
the use of a deep eutectic solvent (DES)-like IL in the development
of self-assembled bimetallic Ag–Au NP films.^228^ The DES was prepared by combining choline chloride and
urea in a 2 molar ratio, which functioned as both a soft template
and substrate and facilitated the controlled self-assembly of Ag–Au
NPs during the thermal evaporation process, ensuring precise nanostructure
formation. The resulting Ag–Au NP film-based SERS substrate
demonstrated high sensitivity for detecting crystal violet and nanoplastics,
providing a LOD of 10^–14^ M for crystal violet and
1 μg mL^–1^ for PET. Zhang et al. highlighted
the potential of IL-based isotropic platforms for highly sensitive
SERS applications and employed ILs as carriers in their study to create
an isotropic SERS platform, shown in Scheme 1.^229^ The N,N′-bis(10-undecenyl)-2-methylimidazolium
bromide ([MImV11,V11^+^][Br^–^]) IL was used in which the coordination effect and anion exchange
capability of the IL was exploited. This approach enabled the successful
growth and stabilization of Au NPs on the polymerized surface of the
IL. A LOD as low as 10^–12^ M was achieved with an
enhancement factor of 3.04 × 10^7^ for methyl orange,
demonstrating the platform’s high sensitivity and potential
for trace detection.
![Scheme 1: Depiction of the Coassembly Strategy of
[MImV11,V11^+^][Br^–^] IL Segments and Further
Synthesis Conducted to Prepare the Ternary Isotropic SERS PlatformReprinted from J. Mol. Liq.,
Vol. 391, Zhang, D.; Zhang, H. Highly sensitive SERS platform on isotropic
ionic liquid-based liposome, pp. 123311 (ref (229)). Copyright 2023, with
permission from Elsevier.](ac5c00264_0008.jpg)
Future Outlook
ILs remain as promising solvents and materials
for a wide range
of analytical applications. Over the last five years, the design of
more selective ILs has been evident for many applications. Optical
sensors have been designed using FILs to detect analytes within complex
samples and enantioseparations using CILs have shown enhanced selectivity
due to synergistic effects. IL membranes have also shown improved
selectivity for CO2 capture and present innovative solutions
for environmental as well as industrial challenges with implications
in sustainability. PILs have also been an important subclass of ILs
with broad applicability from sample preparation to separations to
detection.
Rapid extraction methods using greener solvents remain of interest to achieve high throughput and reduce the use of toxic organic solvents. Miniaturized analytical devices and instruments, ranging from μGC columns and microfluidic devices to mini mass spectrometers and smartphone detectors, have become more prevalent. Additionally, point-of-care and on-site detection methods continue to be a growing area of interest for clinical diagnostics and environmental monitoring. Most prominently, many studies have also demonstrated the cross-disciplinary advantages of their devices, using them for both extraction/separation and detection. This has been observed by coupling in-tube SPME with MS detection, yielding methods that demonstrate high analyte enrichment and lower LODs and LOQs. The coupling of LLE and ABS approaches with microfluidic devices may also offer significant advantages for rapid extraction and detection. Simplification of analytical methods and workflows has advantages in reducing loss of analyte during transfer and sampling errors and in reducing the overall cost of the method.
This review has highlighted many advancements that have been made in the creation of IL-based polymer systems for targeted analytical applications. The versatility of reaction strategies used to prepare PILs have grown significantly in the past decade and will continue to be employed in chemical analysis platforms to prepare polymeric materials at different length scales. It is anticipated that 3D printing approaches employing stereolithography and fused deposition modeling will facilitate more widespread studies using PILs, particularly since there have been tremendous gains in the resolution of commercial printers within the last 5–8 years. Investigations into the design and use of monolithic columns featuring PIL stationary phases for complex chemical separations will continue to expand, along with the development of new approaches to produce PIL microspheres for sample preparation. More sensitive colorimetric and fluorescent assays will be produced using FILs as synthetic chemistry methods will permit a greater mixing and matching of cations/anions to produce compounds with desired optical characteristics.
Within the past 5 years, a greater number of studies have explored deep eutectic solvents (DESs) as sustainable solvents within the field of analytical chemistry compared to the preceding time period. DESs are generally more straightforward to prepare compared to ILs and require little to no purification and cleanup steps. Additionally, their solvation characteristics can often be modulated by choosing the appropriate hydrogen bond donor and hydrogen bond acceptor, which provides them some important advantages over ILs. However, DESs have limited utility at elevated temperatures and their long-term stability need to be carefully monitored. Future attention should be given into understanding the role and tunability of IL chemical structure in the developed methodologies as it pertains to designing better extraction/separation/detection methods and contributing to a deeper knowledge of IL behavior. Advanced analytical methods that can measure important physicochemical properties of ILs (e.g., viscosity, glass transition temperature, conductivity, thermal stability, UV absorption profile, water content) while requiring very little sample will be impactful and can be coupled with advanced computational methods to aid in predicting their properties based on chemical structures and anion/cation combination.