Dear editor,
The indications for ECMO as temporary cardiopulmonary support are growing [1]. Peripheral vascular intubation is usually used in emergency situations [2]. Distal limb necrosis is a common complication of PVAECMO, with an incidence of 10–70% [3]. Indwelling distal perfusion cannula (DPC) is considered to be a common method to prevent ischemic necrosis of distal limbs [4]. However, in clinical practice, it is still difficult to ensure proper perfusion of the lower extremities even if the patient receives DPC indwelling. One of the important reasons for this is the lack of effective perfusion monitoring of the distal limb, which inevitably leads to hypoperfusion or luxury perfusion. The 1/4-inch tube often serves as a bridge connecting the perfusion tube to the DPC (Fig. 1). According to the famous Poiseuille’s law, R = 8nL/(πr^4^), which is Q = Δp/R. Since the resistance properties of the pipeline will not change in a short time, the flow rate can be determined as long as the pressure difference on the pipeline is determined. Due to the characteristics of the DPC, it is difficult to measure the pressure change at both ends of the DPC in a non-invasive manner. The pressure gradient of the 1/4-inch connecting pipe can be selected to measure the flow through the DPC indirectly. Combined with the results of in vitro fluid experiments and clinical observations, under the assumption that the patient’s hemodynamic level and ECMO output power remain unchanged, the pressure at the ends of the 1/4-inch connecting tube is P1, P2 (the pressure near the perfusion tube is P1), ΔP = P1–P2; a decrease in both P1P2 and ΔP occurs when a pipeline obstruction event occurs before the 1/4-inch connection (Fig. 1A). When a conduit obstruction event occurred in the perfusion tube (Fig. 1C), P1, P2, and ΔP all increased. When a pipe-blocking event occurred in the 1/4-inch connection pipe (Fig. 1D), P1 is unchanged, P2 is decreased, and ΔP is increased. When a pipe occlusion event occurred after the 1/4-inch connection (Fig. 1E), P1 remained unchanged, P2 increased, and ΔP decreased. We suggest that routine collateral perfusion tubes for pressure monitoring may help to reduce the incidence of lower limb ischemia as well as to provide localization diagnostic evidence when lower-limb hypoperfusion occurs.
Not applicable.
JY, ZX, XH, CC and LT designed the paper. All authors participated in the drafting and reviewing. All authors read and approved the final manuscript.
None.
The datasets used and/or analyzed during the study are available from the corresponding author on reasonable request.
Not applicable.
The authors declare to have informed consent of the patient to publish the image.
None.
The datasets used and/or analyzed during the study are available from the corresponding author on reasonable request.